8. DIGITAL INPUTS
8.1.2 S.BUS through DJI Lightbridge 1
S.BUS signal from RC transceiver can be sent through DJI Lightbridge 1, so there is no need for the receiver. For
this, you need the DJI Lightbridge 1 and RC transceiver with TRAINER support.
1. Connect the RC transceiver TRAINER port to DJI Lightbridge 1 receiver (mono jack to TRAINER port and
stereo jack to DJI Lightbridge 1).
2. Connect the DJI Lightbridge 1 transceiver S.BUS port to WIRIS S.BUS input.
3. Set up the TRAINER channels in RC transceiver.
This se ng was tested with Futaba T148G RC controller (TRAINER se ng to 12 CH. mode).
Figure 8.6 – DJI Lightbridge 1 TRAINER cable (le ) and S.BUS cable (right).
8.2 Trigger Signal
Aside from the more sophis cated S.BUS control solu on, WIRIS Agro retains a single basic digital input that can
be used for manual capture triggering.
The capture trigger is intended as an op onal, user-implemented fallback. To signal on the trigger input signal,
user is expected to ground the Trigger wire to the GND wire on any of the S.BUS or GPS or CAN connectors.
The triggered signal is triggered with zero or ground on falling edge, the signal should be at least 100 ms long.
Figure 8.7 – Trigger signal