Some chemicals will damage the pump valves if allowed to soak untreated for a long period of time. 

Always flush the pump with water after use. Do not allow chemicals to sit in pump for extended times of idleness.
Follow chemical manufacturers instructions on disposal of all waste water from the sprayer.

— ASSEMBLY INSTRUCTIONS

— AFTER SPRAYING

— WINTER STORAGE

Tools required:

 

1 — 9/16“ End Wrench

 

1 — Thread Sealant

25 GAL. DELUXE SPOT SPRAYER

MODEL # LG 25 DSS

Products  are  warranted  for  two  years  from  date  of  manufacture 

against manufacturer or workmanship defects.

Your authorized dealer is the best source of replacement parts and 

service.  To  obtain  prompt,  efficient  service,  always  remember  to 

give the following information:    1) Correct part description and part 

number.     2) Model number and serial number of your sprayer.

Part  description  and  part  numbers  can  be  obtained  from  the 

illustrated parts list section of this manual.

Whenever you need parts or repair service, contact your distributor 

/ dealer first. For warranty work always take your original sales slip, 

or other evidence of purchase date, to your distributor / dealer.

The pumping system draws solution from the tank, through

the strainer and to the pump. The pump forces the solution

under pressure to the boom nozzles and spray wand.

The  pump  has  a  pressure  switch  which  will  shut  the  pump  off 

when it reaches 60 PSI.

Pressure  may  be  regulated  by  opening    or  closing  the  valve 

located on the top of the tank. See “Valve Operation” illustrated in 

this manual.

Regularly inspect the suction supply screen on the inside

of the tank. Flush with water to clear any accumulated debris.

*This sprayer is designed to be attached to a stable surface.

The purpose of this manual is to assist you in assembling, operating 

and maintaining your lawn and garden sprayer.

Please read it carefully as it furnishes information which will help you 

achieve years of dependable trouble-free operation. 

After use, fill the sprayer part way with water. Start the sprayer 

and allow clear water to be pumped through the plumbing system 

and out through the spray nozzles.

Refill the tank about half full with plain water and use a chemical 

neutralizer such as Nutra-Sol® or equivalent and repeat cleaning 

instructions. Flush the entire sprayer with the neutralizing agent. 

Follow  the  chemical  manufacturer’s  disposal  instructions  of  all 

wash or rinsing water.

Drain all water and chemical out of sprayer, paying special atten-

tion  to  pump  and  valves.  These  items  are  especially  prone  to 

damage from chemicals and freezing weather.

The sprayer should be winterized before storage by pumping a 

solution of RV antifreeze through the entire plumbing. Proper care 

and maintenance will prolong the life of the sprayer.

• Polyethylene Tank
• 12 Volt Diaphragm Pump
• 2.0 G.P.M.
• Lever Handgun
• 15 Ft. of 3/8” Hose (Handgun)
• Pressure Gauge
• Adjustable Pressure Range (0-60 PSI Max.)

PRECISION SPRAY EQUIPMENT, a divison of Green Leaf, Inc.   9490 N BALDWIN ST   FONTANET, IN 47851   www.workhorsesprayers.com

a division of Green Leaf, Inc

®

P R E C I S I O N   S P R AY   E Q U I P M E N T

PSE

Assembly / Operation Instructions / Parts

WORKHORSE

WORKHORSE

S   P   R   A   Y   E   R   S

by PSE, a Division of Green Leaf, Inc®

by PSE, a Division of Green Leaf, Inc®