Inspection and maintenance
55
Greenstar 8000 Life – 6720883865 (2019/02)
Fig. 84 Cleaning debris
▶ Refit the cleaning access cover assembly in reverse order the new
seal [2], and the access cover [1].
▶ Hand tighten the bolts and then use a spanner to tighten the bolts a
further half turn.
Fig. 85 Re-fitting the access cover
▶ Ensure that the convex side of the burner faces down into the heat
exchanger when re-fitting the burner.
▶ Ensure seal is replaced with new seal and is correctly fitted.
▶ Check the siphon unit is clean before refitting to appliance.
On completion of the heat exchanger cleaning and reassembly, perform
the fan pressure test.
8.9.5
Checking electrodes
▶ Remove the electrode set with gasket.
▶ Check electrodes for contamination.
▶ Clean or replace electrodes if required.
▶ Install electrode set with new gaskets.
Fig. 86 Installing electrode set
▶ Check integrity of seal of electrode set. Using a mirror to check for
misting.
Fig. 87 Checking for leaks with an inspection mirror. Observe for
misting.
8.9.6
Cleaning the siphon
Cleaning the condensate trap
WARNING:
Danger to life due to poisoning!
If the condensate trap is not filled, poisonous flue gas can escape.
▶ Only turn off the siphon filling program during maintenance, and turn
it back on at the end of maintenance.
▶ Make sure that the condensate drains off properly.
Damages resulting from an insufficiently cleaned condensate trap are
excluded from the warranty.
▶ Clean the condensate trap regularly.
1. Whilst supporting the condensate trap, firmly press the unlock
mechanism, until an audible click is heard.
2. Pull the condensate trap forwards and tilt to the left for draining.
0 010 007 129-001
0010023584-001
1
2
0010026738-001
0010007499-003