Installation
31
Greenstar 8000 Life – 6720883865 (2019/02)
Fig. 40 Connections on the gas and the water side
[1]
Heating flow valve
[2]
Hot water
[3]
Gas isolator
[4]
Cold Water inlet
[5]
Keyless filling link
[6]
Heating return valve
Preparing the pre-plumbing manifold
▶ Fit sealing washers to service valves before hanging appliance.
Fig. 41 Fitting the sealing washers
[1]
CH flow (22mm)
[2]
DHW outlet (15mm)
[3]
Gas inlet (22mm bonded washer)
[4]
Domestic Cold Water inlet (15mm)
[5]
CH return (22mm)
Before hanging the appliance onto the wall mounting frame ensure that
the pressure relief Drain Pipe is connected securely.
▶ Apply a smear of silicone lubricant to the seal to ease connection
later.
Fig. 42 Connect PRV discharge pipe
Fitting the condensate pipework
▶ Secure the pipe to the wall at the last joint.
▶ Ensure the pipe protrudes through the pre-plumbing manifold by
25mm.
▶ If exiting through the wall, to run externally, the pipe must have a 3°
fall and be increased to a 32mm insulated pipe.
Fig. 43 Fitting the condensate pipes to the mounting plate
0010023239-001
00100
4
5
6
1
2
3
0010023570-001
3
4
5
1
2
0010023277-001
1.
4.
2.
3.
25mm
6720806944-04.1W
o