6.1 - Maintenance on the 3 rings
Regular maintenance of the three-ring system is essential and should be
done at least once a month.
We therefore recommend following these simple step-by-step operations
to ensure efficient operation of the system.
First remove the handle by pulling the yellow release cable completely out
of the flexible metal sleeve. Proceed by cleaning both release cables with
silicon lubricant and check that they are not damaged or bent at any point.
Then check the rings themselves for any deformations, cracks or traces of
corrosion; the same should be done for the eyelet.
The release rings must be cleaned and lubricated with a silicon lubricant and
we recommend cleaning the sheaths as well to avoid dust accumulation.
Then move on to inspect and clean the straps where the rings are attached.
We suggest moving them, massaging them vigorously and rotating them to
make the straps lose the memory of their previous position.
As a last step, inspect the white locking loop for signs of wear, replacing it
if necessary.