Woodward Flo-Tech 8400-511 Скачать руководство пользователя страница 1

 

 

 
 
 

Hardware Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Digital Min/Max Flo-Tech™ Control 

8400-511 

 
 
 
 

for Cummins Jade/Bravo Engines 

 

 
 
 
 

Manual 04168 

 

 

 

Содержание Flo-Tech 8400-511

Страница 1: ...Hardware Manual Digital Min Max Flo Tech Control 8400 511 for Cummins Jade Bravo Engines Manual 04168...

Страница 2: ...nce this copy was produced To verify that you have the latest revision be sure to check the Woodward website www woodward com pubs current pdf The revision level is shown at the bottom of the front co...

Страница 3: ...3 DESCRIPTION OF OPERATION 11 Introduction 11 Digital Min Max Flo Tech Control 11 Control Adjustment PC Service Tool 11 The Flo Tech Actuator 11 Return Spring 12 Control Operation 12 Control Features...

Страница 4: ...m materials such as plastic or Styrofoam cups cup holders cigarette packages cellophane wrappers vinyl books or folders plastic bottles and plastic ash trays away from the control the modules and the...

Страница 5: ...r operation of a power take off used with handicapped access lifts or kneeling buses The throttle is disabled during this selection Transmission Signal Provides a voltage or current signal to transmit...

Страница 6: ...Digital Min Max Flo Tech Control Manual 04168 2 Woodward Figure 1 1 Typical System Layout...

Страница 7: ...Manual 04168 Digital Min Max Flo Tech Control Woodward 3 Figure 1 2 Digital Min Max Flo Tech Control Box...

Страница 8: ...Digital Min Max Flo Tech Control Manual 04168 4 Woodward Figure 1 3 Typical Flo Tech Outline Drawing...

Страница 9: ...Manual 04168 Digital Min Max Flo Tech Control Woodward 5 Figure 1 4 Network Connection Example...

Страница 10: ...Digital Min Max Flo Tech Control Manual 04168 6 Woodward Figure 1 5a Plant Wiring Diagram...

Страница 11: ...Manual 04168 Digital Min Max Flo Tech Control Woodward 7 Figure 1 5b Plant Wiring Diagram...

Страница 12: ...Vdc 12 or 24 Vdc nominal The system consumes a maximum of 23 watts nominal Mounting the Control The control box is designed to operate within a temperature range of 40 to 60 C 40 to 140 F Mount the c...

Страница 13: ...tors The DMMF interfaces to the engine and vehicle systems through two 23 pin AMP connectors The Woodward part numbers for these parts as well as the actuator connector part number s are located on th...

Страница 14: ...nts See Woodward application note 50532 Interference Control in Electronic Governing Systems for more information Where shielded cable is required cut the cable to the desired length and prepare the c...

Страница 15: ...control layout and wiring see the plant wiring diagram Figure 1 5 The control operates on either 12 or 24 Vdc vehicle battery systems within a range of 8 to 32 Vdc Control Adjustment PC Service Tool T...

Страница 16: ...ortional to the position of the throttle pedal If a foot pedal fault is detected the engine is forced to idle speed If the control detects an actuator short or position sensor fault the control drives...

Страница 17: ...these features are enabled Cruise Control On Off Contact also PTO On Off Contact This contact input indicates to the control when the user enables the Cruise Control feature The control receives a bat...

Страница 18: ...pecifically for vehicle applications The control automatically varies its control dynamics as functions of both speed and actuator position to provide better performance over the operation range of th...

Страница 19: ...distributor handles repairs replacements and warranties and handles sending the control through Cummins Engine Company to Woodward Packing a Control Use the following materials when returning a contr...

Страница 20: ...iated Susceptibility not susceptible to radiated emissions up to 100 V m in the range of 20 kHz to 400 MHz and 50 V m from 400 MHz to 1 GHz at an amplitude of 50 V m Conducted Susceptibility from 30 H...

Страница 21: ...0 5 Vdc Wiper Input Impedance 50 k 5 Supply Voltage 5 V at 80 mA supplied by the DMMF control Vehicle Sensor Supply Connections J2 16 C pedal connector J2 3 0 B pedal connector J2 17 A pedal connecto...

Страница 22: ...dc voltage same as control input supply voltage Maximum Current 500 mA Max Load Impedance 7 5 k at 32 Vdc Min Load Impedance 16 at 8 Vdc Connections J2 9 fault indicator other side of load to control...

Страница 23: ...Input Response time 50 ms 25 Min Input High Voltage 8 Vdc Connections J2 21 through dash mounted switch to battery typically I O Parameter Cruise Control Resume Switch Input Type contact input Input I...

Страница 24: ...Drake Road Fort Collins CO 80525 USA Phone 1 970 482 5811 Fax 1 970 498 3058 Email and Website www woodward com Woodward has company owned plants subsidiaries and branches as well as authorized distr...