Rev 3.0/7-15
13
FLEXR(L)-HV11AIR: #35036
Monitoring the Vacuum Gauge
The vacuum gauge must remain completely visible to the operator, so that it can be monitored
throughout the entire lift.
WARNING: Vacuum gauge must be visible to operator throughout entire lift.
The lifter’s vacuum pump runs continuously to maintain sufficient vacuum for lifting the
maximum load weight. If the vacuum system experiences leakage while the lifter is attached to
the load, the vacuum gauge signals the reduction in vacuum to the operator. Make sure the
vacuum gauge shows a vacuum level of 16" Hg [-54 kPa] or higher while you are lifting a load.
If not, move away and stay clear of the load until it can be lowered to the ground or a stable
support.
WARNING: Stay clear of any suspended load while vacuum level is lower than
16" Hg [-54 kPa].
Discontinue lifter use until the cause of the vacuum loss can be determined. If the vacuum level
remains lower than 16" Hg [-54 kPa] when the lifter is attached to clean, smooth, nonporous
materials, the leakage is likely to be in the vacuum system. In this event, perform the V
ACUUM
T
EST
(see MAINTENANCE) and inspect the vacuum pads for damage (see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Inspection). If the vacuum loss cannot be remedied immediately, perform
inspection and maintenance as needed to identify and correct any deficiency before resuming
normal operation of the lifter.
Controlling the Lifter and Load
When the vacuum gauge shows that the lifter is ready, use the
hoisting equipment to raise the lifter and load as needed to
clear any obstacles in their path. Use the control handles to
keep the lifter and load in the desired orientation while they are
suspended from the crane.
Note: Depending on the arrangement of sliding pad arms and movable pad mounts, the pad
frame may extend beyond the edges of smaller loads. When moving such loads, be careful to
avoid any obstacles to the pad frame, as well as to the load.
In Case of Power Failure
The lifter is equipped with a vacuum reserve tank, designed to maintain vacuum temporarily in
case of a power failure.
WARNING: Stay clear of any suspended load in the event of a power failure.
Although the lifter is designed to support the load for at least 5 minutes without power, this
depends on many factors, including the condition of the load and the lifter’s vacuum system (see
INTENDED USE: L
OAD
C
HARACTERISTICS
and MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
,
V
ACUUM
T
EST
). If a power failure occurs, keep all personnel clear of the suspended load until it can safely
be placed on the ground or a stable support. Correct any deficiency before resuming normal
operation of the lifter.