Wood’s Powr-Grip MRTALPCH610DCO Скачать руководство пользователя страница 16

Rev 8.0/6-13 

14 

MRTALPCH6-DC: #35054 

T

A

PPLY THE 

P

ADS TO A 

L

OAD

 

Positioning the Lifter on the Load 

Make certain that the contact surfaces of the load and all vacuum pads are free of any 

contaminates that could prevent the pads from sealing against the load (see MAINTENANCE: 

V

ACUUM 

P

AD 

M

AINTENANCE

). 

Center the lifter’s pad frame to within 2" [5 cm] of the load center, since off-center loading can 

cause the load to rotate or tilt unexpectedly (see T

R

OTATE THE 

L

OAD 

E

DGEWISE

 or T

T

ILT THE 

L

OAD

 

to follow), and it may also damage the lifter.

8

    Make sure that all vacuum pads will fit entirely on 

the load’s contact surface (see SPECIFICATIONS: Pad Spread) and that they will be loaded 

evenly while lifting (see SPECIFICATIONS: Per-Pad Load Capacity).    Then apply the lifter to the 
load so that all pads are touching the contact surface. 

Powering up the Lifter 

Place the lifter's power switch in the ON (      ) position.

9

    The blue power light remains 

illuminated while the lifter is powered up.    Keep the power switch in the ON position while lifting 
a load.    Any power interruption during a lift could result in the release of a load and possible 
injury to the operator or others (see T

L

IFT AND 

M

OVE THE 

L

OAD

: In Case of Power Failure to 

follow). 

WARNING:    Never turn power off while lifting. 

If the lifter is equipped with a Remote Control System, press the transmitter power/enable button 

and hold it briefly to activate the radio transmitter.

10

    This button is also used to activate the 

enable function (see T

R

ELEASE THE 

P

ADS FROM THE 

L

OAD

 to follow). 

Note:    If the transmitter is activated, the transmission indicator light flashes green when any 

button on the transmitter is pressed and held; if the transmitter is not activated, the indicator 
light flashes red (see B

EFORE 

U

SING THE 

L

IFTER

: Preparing to Use the Optional Remote Control 

System preceding). 

Sealing the Pads against the Load 

Firm pressure at the center of the lifter helps the vacuum pads begin to seal against the load.   

Press an apply button on the lifter or the optional radio transmitter to make sure the apply 
function is activated.    This energizes the vacuum pump, causing air to be drawn at the pads 

immediately.    The low vacuum warning buzzer also sounds an alarm until the lifter attains 
sufficient vacuum to lift the maximum load weight (see T

L

IFT AND 

M

OVE THE 

L

OAD

: Interpreting 

the Warning Buzzer and Lift Light to follow).    The lifter must remain in the apply mode 
throughout the entire lift. 

                                        

8

    The lifter is designed to handle the maximum load weight (see SPECIFICATIONS: Maximum Load Capacity) when the load’s 

center of gravity is positioned within 2" [5 cm] of the pad frame's center point.    Occasional loading deviations are permissible, 

provided that the operator can maintain control of the load at all times and that the load weight is low enough to avoid damaging 
the lifter. 

9

    When the operator powers up the lifter, either the stand-by function or the apply function is automatically activated, 

depending on which was used last. 

10

    The radio transmitter turns off automatically, after a period of inactivity.    The operator can also operate the lifter without 

using the radio transmitter, if desired. 

Содержание Powr-Grip MRTALPCH610DCO

Страница 1: ...e see serial label and record number here MANUAL ROTATOR TILTER LOW PROFILE DC VOLTAGE WITH DUAL VACUUM SYSTEM AND CHANNEL STYLE PAD FRAME READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS LIFT...

Страница 2: ......

Страница 3: ...es 8 To Install Remove Pad Frame Extensions 9 INTENDED USE 10 LOAD CHARACTERISTICS 10 OPERATING ENVIRONMENT 11 DISPOSAL OF THE LIFTER 11 OPERATION 12 BEFORE USING THE LIFTER 12 Taking Safety Precautio...

Страница 4: ...E CONTROL SYSTEM TEST 26 AIR FILTER MAINTENANCE 27 Filter Function and Conditions Requiring Service 27 Filter Service Procedures 27 VACUUM PUMP MAINTENANCE DYNAFLO DV1032102 28 Replacing the Diaphragm...

Страница 5: ...to maintain vacuum Vacuum Gauges 2 dial gauges indicate current vacuum level in positive inches of Hg and negative kPa Vacuum Lift Light Green light is energized whenever vacuum is higher than the le...

Страница 6: ...tly on the load prior to lifting see OPERATION TO APPLY THE PADS TO A LOAD Never lift a load when any vacuum indicator shows inadequate vacuum Never touch the vacuum release controls during a lift Thi...

Страница 7: ...RY GAUGE 19 VACUUM GAUGE 2 BATTERY CHARGER 11 ENABLE BUTTON 20 ROTATION RELEASE LEVER 3 VACUUM RESERVE TANK 12 APPLY BUTTON 21 Cover for AIR FILTERS 4 Cover for BATTERY 13 RADIO RECEIVER optional 22 Q...

Страница 8: ...Rev 8 0 6 13 6 MRTALPCH6 DC 35054 1 TRANSMISSION INDICATOR LIGHT 2 TRANSMITTER POWER ENABLE BUTTON 3 RELEASE BUTTONS 4 APPLY BUTTONS 5 EMERGENCY TRANSMITTER DISCONNECT OPTIONAL RADIO TRANSMITTER...

Страница 9: ...applicable rated to carry the maximum load weight plus the lifter weight see SPECIFICATIONS Maximum Load Capacity and Lifter Weight Note Any application of the lifter must conform to all statutory or...

Страница 10: ...o the vacuum pads located on the extensions WARNING Removing any extension or disconnecting the corresponding vacuum pad reduces load capacity of lifter To support smaller dimensions and weights the p...

Страница 11: ...ion that is equipped with a control handle should be installed on the lower end of the pad frame ie when oriented vertically 3 Align the bolt holes in the pad frame extension with the bolt holes in th...

Страница 12: ...of the load are determined by the Pad Spread see SPECIFICATIONS the maximum length and width are determined by the allowable overhang or the amount of load material that can extend sideways beyond th...

Страница 13: ...ECIFICATIONS The lifter s work environment must be free of metal particles or any other contaminates that could damage lifter components through airborne contact or any other means of transmission in...

Страница 14: ...ry energy before using lifter See MAINTENANCE BATTERY TEST Perform all inspections and tests required by the INSPECTION and TESTING SCHEDULES see MAINTENANCE In addition if the lifter has been in stor...

Страница 15: ...System the operator can engage the lifter s apply and release functions at distances up to 250 ft 76 m provided there is a direct and clear view of the lifter and its status indicators from the opera...

Страница 16: ...function see TO RELEASE THE PADS FROM THE LOAD to follow Note If the transmitter is activated the transmission indicator light flashes green when any button on the transmitter is pressed and held if...

Страница 17: ...Other Surfaces When the lifter is attached to contaminated rough or porous load surfaces it may not be able to maintain a vacuum level in the green range on both vacuum gauges due to leakage in the s...

Страница 18: ...monitored throughout the entire lift WARNING Vacuum indicators must be visible to operator throughout entire lift If the vacuum system experiences leakage while the lifter is attached to the load the...

Страница 19: ...between the vacuum pads and the load Since the alarm may sound in such circumstances consult the section TO APPLY THE PADS TO A LOAD Vacuum Level on Other Surfaces to determine whether the lifter can...

Страница 20: ...y other position WARNING Make sure load is positioned correctly on lifter see TO APPLY unbalanced loads may rotate unexpectedly when latch is disengaged Remember that the load is longer in its diagona...

Страница 21: ...sition pull the tilt release lever to disengage the tilt latch Lift upward or press downward on the control handle to tilt the load as desired If load size permits maintain control with the handle thr...

Страница 22: ...uld soil or damage the vacuum pads Use the hoisting equipment to gently lower the lifter onto a stable support then detach the hoisting equipment hook from the lift spool If the lifter is transported...

Страница 23: ...ours use or whenever lifter is out of service for 1 month or more Examine the lifter s structure for visual damage Examine the vacuum system including vacuum pads fittings and hoses for visual damage...

Страница 24: ...ICATIONS using an actual load or an equivalent simulation 13 Employ the following method to test with an actual load 1 Place a test load with appropriate LOAD CHARACTERISTICS see INTENDED USE on a sta...

Страница 25: ...is not in stand by mode However the battery gauge shuts off temporarily while the vacuum pump is running to prevent an inaccurate reading When the pumping cycle is completed the battery gauge requires...

Страница 26: ...ctioning correctly the energy reading should be higher when the charger is plugged in VACUUM PAD MAINTENANCE Friction Coefficient The friction coefficient represents the lifter s ability to resist loa...

Страница 27: ...include soapy water and other mild cleansers Do not use solvents petroleum based products including kerosene gasoline and diesel fuel or any harsh chemicals for cleaning Do not use unauthorized rubber...

Страница 28: ...er to verify that functions are being performed as intended If the Remote Control System does not function correctly review the following potential causes of malfunction and correct them as directed T...

Страница 29: ...ovable end 2 counter clockwise approximately 45 until it stops moving 2 Pull the end outward from the case and remove the filter element 3 Use an air hose or other suitable means to remove any liquid...

Страница 30: ...n the illustration Replacing the Gasket Flap Valves 1 Remove the four head screws 1 and lock washers 2 and remove the head assembly 3 7 2 Invert the head and remove the two valve plate screws 7 Remove...

Страница 31: ...four head screws 1 and remove the head 2 2 Invert the head and remove the four valve plate screws 9 3 Lift out the valve plate 6 to access the exhaust valve flapper and head gasket 22 4 Remove the exh...

Страница 32: ...o lift the maximum load weight If the pump and the warning buzzer do not turn on or the lift light does not turn off before vacuum decreases to a level lower than the minimum lifting level the vacuum...

Страница 33: ...ain a lower vacuum level turn the screw clockwise To maintain a higher vacuum level turn the screw counter clockwise 2 Recheck the vacuum switch setting following each 1 6th turn of the adjustment scr...

Страница 34: ...line for radio transmitter 2 64664 Battery 12 V DC 7 Amp Hours 1 64590 Battery Gauge 1 64460 Circuit Breaker 15 A 1 64453CP Circuit Board Populated 1 64271 Strobe Light 12 V DC Amber option 1 64238BA...

Страница 35: ...use Repairs are required due to abnormal wear and tear The product has been damaged misused or neglected If a problem is not covered under warranty Powr Grip will notify the customer of costs prior to...

Страница 36: ...Rev 8 0 6 13 34 MRTALPCH6 DC 35054...

Страница 37: ...Rev 8 0 6 13 35 MRTALPCH6 DC 35054...

Страница 38: ...Rev 8 0 6 13 36 MRTALPCH6 DC 35054...

Отзывы: