background image

 
 
 
 

 

 

 

 

 

 

 

 
 

For more information contact… 

WOODFORD MANUFACTURING COMPANY 

2121 Waynoka Road, Colorado Springs, Colorado 80915 • Phone: (800) 621-6032 • Fax: (800) 765-4115 

To view our complete product line visit:A Division of WCM Industries, Inc. 

 

X34 Yard Hydrant 
Packing Replacement 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev 06/10 Form No.TMYH-15.103 

 

 

 

 

 

Blue Head 
Assembly 

If a persistent leak is detected after tightening the 
Packing Nut, follow these instructions for replacing the 
Packing: 

1. 

Shut off water supply to hydrant.

 

2. 

Loosen the Pivot Set Screw. Fig 1

 

3. 

Loosen, 

do not remove

, the Packing Nut. Fig 1

 

4. 

Remove head casting using two pipe wrenches, 
one on head casting and the other on the pipe. 
Fig 1

 

5. 

Remove the Link Bolt and Link Spacer then 
remove and set aside the Handle and Linkage 
Assembly. Fig 1

 

6. 

Remove the Packing Nut. Fig 2

 

7. 

Dig out the graphite Packing with a screwdriver 
or other instrument. 

Note: This operation will 

destroy the Packing and require a new Packing 
#10101.

 

8. 

The Packing Washer #10102 may be reused.  

 

9. 

Install new Packing #10101.

 

10. 

Reinstall the Packing Nut - 

do not tighten.

 

11. 

Reinstall the Handle and Linkage Assembly.

 

12. 

Align and carefully reinstall the Head Assembly 
over the Brass Stem and thread onto the Pipe 
Casing. 

Note: Turn Head Assembly down 

enough so the Set Screw in the Pivot will 
engage the Brass Stem.

 

13. 

Tighten Packing Nut until water stops leaking.

 

14. 

Adjust linkage so handle will snap closed at very 
end of closing. 

See 

“Linkage Adjustment”

 

 

Fig 1 

Fig 2 

Packing Nut 

Packing 

Packing Washer 

Head Casting 
(Wrench Location) 

Brass Stem 

Pipe Casing 
(Wrench Location) 

Pivot Set Screw 

Handle & 
Linkage 
Assembly 

Packing Nut 

Pivot 

Содержание X34

Страница 1: ...nally need to be tightened to stop a packing leak Tighten the packing nut until snug and the leak stops Persistent leaks will require a new packing 10101 See X34 Packing Replacement instructions 3 Water leaks from below ground level when the hydrant is on A small leak may be the result of a leak at the drain hole Replace the plunger if it is old and worn See Operating Rod Assembly Removal instruct...

Страница 2: ...adjustment can be made with the water supply on by tightening the Packing Nut enough to hold the hydrant closed To increase the Handle tension With the Handle in a closed position loosen the Set Screw in the side of the Pivot Fig 1 Lift the Handle to the desired position and reset the Set Screw Fig 2 The Handle at the end of the closing stroke should snap closed against the Head Casting Fig 2 To d...

Страница 3: ...ve operating rod by gripping pipe with vice grips and prying upward DO NOT attach vice grips to brass stem Damage to stem may cause leakage around packing nut Fig 2 6 Turn on water and allow to flow and flush the casing 7 Examine plunger for damage and replace if necessary Fig 3 7a Remove plunger from operating rod with either pipe wrenches or vise grips 7b Install new Plunger 10108 Fig 3 8 Apply ...

Страница 4: ...nk Spacer then remove and set aside the Handle and Linkage Assembly Fig 1 6 Remove the Packing Nut Fig 2 7 Dig out the graphite Packing with a screwdriver or other instrument Note This operation will destroy the Packing and require a new Packing 10101 8 The Packing Washer 10102 may be reused 9 Install new Packing 10101 10 Reinstall the Packing Nut do not tighten 11 Reinstall the Handle and Linkage...