Wood Stone PHOENIX 4343 Скачать руководство пользователя страница 1

Tel +1.360.650.1111
Fax +1.360.650.1166

www.woodstone-corp.com

WOOD STONE CORPORATION

1801 W. Bakerview Rd.
Bellingham, WA 98226   USA

PHOENIX OVEN

Stone Hearth Oven

Dual Radiant Flame Burners, Gas-Fired Models

PHOENIX 4343 PITA OVEN 

WS-BL-4343-RFG-LR

PHOENIX 4355 PITA OVEN 

WS-BL-4355-RFG-LR

PHOENIX 4836 PITA OVEN 

WS-BL-4836-RFG-LR

DOC NO  

M0030.07

  REVISED  

APRIL 2017

Installation and  

Operation Manual

Содержание PHOENIX 4343

Страница 1: ...view Rd Bellingham WA 98226 USA PHOENIX OVEN Stone Hearth Oven Dual Radiant Flame Burners Gas Fired Models PHOENIX 4343 PITA OVEN WS BL 4343 RFG LR PHOENIX 4355 PITA OVEN WS BL 4355 RFG LR PHOENIX 4836 PITA OVEN WS BL 4836 RFG LR DOC NO M0030 07 REVISED APRIL 2017 Installation and Operation Manual ...

Страница 2: ...OF CONTENTS DUAL BURNER PHOENIX OVEN 3 CAUTIONS WARNINGS 4 PX 4343 LR SPECIFICATIONS 6 PX 4355 LR SPECIFICATIONS 7 PX 4836 LR SPECIFICATIONS 8 MOVING PLACING THE OVEN 9 INSTALLATION CLEARANCES 10 VENTING 11 LIFTING THE OVEN 12 EXPLODED PARTS DIAGRAM 14 ASSEMBLY 15 UTILITY CONNECTIONS 20 STORAGE BOX INSTALLATION 22 CONTROLLER 23 INITIAL START UP 24 INITIAL START UP 24 OVEN OPERATION 25 DAILY MAINTE...

Страница 3: ... AVAILABLE UPON REQUEST Dual Burner Phoenix Installation and Operation Manual PG 3 OF 32 M0030 07 APRIL 2017 An ongoing program of product improvement may require us to change specifications without notice WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA TEL 1 360 650 1111 FAX 1 360 650 1166 E MAIL info woodstone corp com woodstone corp com DUAL BURNER PHOENIX OVEN Shown WS PX 43...

Страница 4: ...allation ou entretien INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE PHOENIX NATURAL GAS NG OR PROPANE LP FUELED DUAL BURNER STONE HEARTH OVEN WS PX 4343 RFG LR NG OR LP WS PX 4355 RFG LR NG OR LP ADDITIONAL COPIES AVAILABLE UPON REQUEST READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE Please read this entire manual before you install the oven Failure to follow instructions m...

Страница 5: ... installed This appliance needs an unobstructed flow of fresh air for satisfactory combustion and must be installed in a suitably ventilated room in accordance with current regulations This appliance should be serviced by qualified personnel at least every 12 months or sooner if heavy use is expected A MAJOR CAUSE OF OVEN RELATED FIRES IS A FAILURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE MA...

Страница 6: ...0mm OD 4 1 4 110mm 10 1 2 270mm 69 3 4 1770mm 9 1 2 240mm 120VAC 4A Model D W BTU hr WS BL 4343 42 1 4 in 1080 mm 42 1 4 in 1070 mm 105 000 NG 100 000 LP REV LEGEND PART WS BL 4355 shown BL RFG LR Pita Oven All Sizes General Arrangement 5 30 2013 bena 1 DWN BY SHEET 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES CES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE ATION CONTAINED IN ...

Страница 7: ...4 1 4 110mm 10 1 2 270mm 69 3 4 1770mm 9 1 2 240mm 120VAC 4A Model D W BTU hr WS BL 4343 42 1 4 in 1080 mm 42 1 4 in 1070 mm 105 000 NG 100 000 LP REV LEGEND PART WS BL 4355 shown BL RFG LR Pita Oven All Sizes General Arrangement 5 30 2013 bena 1 DWN BY SHEET WA 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES RANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE ORMATION CONTAINED I...

Страница 8: ...ROVEMENT QUIRE US TO CHANGE SPECIFICATIONS WITHOUT NOTICE DATE 1 of 1 AIR INTAKE G D 24 1 2 620mm 6 150mm 6 1 2 160mm 6 1 2 160mm 1 1 2 40mm 7 1 2 190mm 47 1200mm 37 940mm 7 1 2 190mm 40 1020mm 2 1 2 70mm W 7 1 2 190mm 9 3 4 250mm O 10 250mm OD 4 1 4 110mm 10 1 2 270mm 69 3 4 1770mm 9 1 2 240mm 120VAC 4A Model D W BTU hr WS BL 4343 42 1 4 in 1080 mm 42 1 4 in 1070 mm 105 000 NG 100 000 LP REV LEGE...

Страница 9: ...staller does not have the equipment or experience required to move the oven safely we recommend securing the services of a qualified rigging company Ü Ü Make sure the Pallet Jack wheels do not contact the underside of the fork pocket when lifting to avoid damaging the stand PICKEYE CAPACITIES PER BEAM 2 000 lbs Middle holes PX 4343 LR PX 4355 LR 2 700 lbs Outer holes PX 4836 LR INNER INNER MIDDLE ...

Страница 10: ...G OR SERVICING THIS APPLIANCE Please read this entire manual before you install the oven Failure to follow instructions may result in property damage bodily injury or even death Contact your local building or fire officials about restrictions and installation inspection in your area WARNING Do not pack required air spaces clearance with insulation or other material EN AVERTISSANT n emballez pas le...

Страница 11: ...tack or curb mounted fan Wood Stone does not recommend the use of an in line fan A static pressure of 0 25 mbar 0 1 inches water column is necessary at the oven flue collar to ensure proper flue temperatures at the fan The airflow required to attain this static pressure will depend on the configuration of your particular installation but will be approximately 400CFM The exhaust fan must be turned ...

Страница 12: ...A DISASSEMBLED BISTRO OVEN THROUGH A NARROW DOOR OR PASSAGEWAY USING THE OPTIONAL LIFTING SYSTEM An optional Lifting System is available from Wood Stone to facilitate tipping the oven body onto its back or side as shown below When turned on its side the upper oven portion of Bistro or Phoenix models 4343 4355 and 4836 will be approximately 32 inches wide This will allow for easier access through s...

Страница 13: ... move the oven in this manner on any type of incline or sloped floor 10 Once the oven is on the other side of the passageway attach strap to the clevises at the Lifting Holes on the Crosspiece and with a gantry crane lift the oven straight up Remove pallet jack Lower the oven onto 4x4 blocks 11 Move strap to the clevises at the top of the Pickeye Inserts and tilt the oven down onto the 4x4 blocks ...

Страница 14: ...TEL 1 360 650 1111 FAX 1 360 650 1166 E MAIL info woodstone corp com woodstone corp com EXPLODED PARTS DIAGRAM With the exception of the temporary Shipping Panel all parts shown below including the Rear Panel MUST be installed to ensure the safe and proper operation of the oven Oven Body Control Box Flame Guards Front Panel Toe Kick Rear Panel Shipping Panel Only on export ovens shipped disassembl...

Страница 15: ... to shim the oven for leveling purposes it is critical that the shim material be metal and that the shims are installed in such a way that the full perimeter of the stand is solidly supported Any gaps created by shimming between the oven and the floor must be sealed for proper ventilation Failure to solidly support the full perimeter of the oven stand can result in costly damage to the oven and wi...

Страница 16: ...ven is to be installed against a wall leave access to the back of the oven until the assembly is completed CAUTION The 4343 4836 model Phoenix weighs approximately 930 kg The 4355 model Phoenix weighs approximately 1134 kg The oven is very top heavy If the oven tips it can cause severe injury or death The oven should only be moved in this manner pallet jack on a LEVEL FLOOR Do not attempt to move ...

Страница 17: ...e oven The shipping panel is secured with 2 screws in the front and 2 screws in the back Discard the shipping panel 7 Install Burner Assemblies A Position burner as shown Note Gas connections will be towards front of oven B Raise burner s up into burner slot s Secure with the 1 4 20 bolts provided Tighten nuts securely 6 Attach the Control Box to the oven using 4 1 4 20 screws The Control Box shou...

Страница 18: ...lug in Thermocouple Wire here Attach flexible Pilot Tubes between the SV 2 SV 3 Gas Valves and left right Burners Tighten the fitting firmly Use Flexible Gas Pipe provided to connect the Burner left and right Plug in Igniter Wires from the Burners into the SV 2 and SV 3 Gas Valves 9 Install the Mantle Fasten using 3 bolts washers and 2 carriage bolts see illustration If the oven has been supplied ...

Страница 19: ...USA TEL 1 360 650 1111 FAX 1 360 650 1166 E MAIL info woodstone corp com woodstone corp com ASSEMBLY 11 Run a bead of high temperature silicone provided along visible joints where the mantle and the oven intersect in the front and down both sides of the oven right side not shown 12 Reinstall the Burner Guards The lower tab of the guard fits into the front of the burner opening Lower tab of Burner ...

Страница 20: ... gas supply near the oven in such a way that it is readily accessible This appliance must be electrically grounded in accordance with local code or in the absence of local code with the national electrical code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable An electrical diagram is provided inside the bottom cover of the Control Box and at the end of this manual Connect the i...

Страница 21: ...ECKING THE BURNER MANIFOLD PRESSURES The burner manifold pressures have been set at the factory However they should be checked by the installer The pressures should be checked at the outlet tap on each Honeywell gas valve located on the back of the control box Once the manometer is connected turn the oven on and use the knob on the oven to adjust the flame to its maximum height Then check the mani...

Страница 22: ...nnector 1 Install Toe Kick w perforations using 3 provided 1 4 20 screws a 2 Slide Storage Box into front of oven flush to side panel flanges and Toe Kick Fasten using 4 provided 1 4 20 screws b 3 Tuck Storage Box Connector under control panel and over top of Storage Box Fasten using 2 provided 1 4 20 screws c b a a a b b b c c Dual Burner Phoenix Installation and Operation Manual PG 22 OF 32 M003...

Страница 23: ...mperature Dual burner models have 2 knobs which are linked together see Burner Disable Switch at right Flame Height Control Knob right Burner Disable Switch Use this switch to disable one of the burners specify which burner will be disabled at time of order Controller Dual Burner Phoenix Installation and Operation Manual PG 23 OF 32 M0030 07 APRIL 2017 An ongoing program of product improvement may...

Страница 24: ...cked to the appliance 2 Make sure main gas supply is ON valve parallel with gas line 3 Push I O button on controller The exhaust fan should come on as well It may take a while for the gas to purge all the air from the gas lines Verify both burners light If only one is lite check that the Burner Disable switch on the front panel is in the ON position 4 Once the burner s ignite s make sure the flame...

Страница 25: ...n cooking in your Wood Stone oven OVEN INTERIOR Wood Stone recommends the use of long handled brushes for sweeping up surface debris that will accumulate on the floor of the oven during use Use a natural fiber brush always brushing away from the radiant burner well For deeper cleaning use a brass bristled brush The oven floor can be then cleaned with a damp rag wrapped around the brass bristled br...

Страница 26: ... If you operate the oven below 232 C 450 F you may also notice some buildup on the interior walls and or ceiling of the oven To remove any buildup that has accumulated inside of the oven simply turn the radiant flame to its highest setting Monitor the hearth floor temperature displayed on the controller When the floor reaches 343 C 650 F lower the flame slightly so as to maintain the oven floor te...

Страница 27: ...ributor for assistance PROBLEM CAUSE SOLUTION 1 Check gas is turned on to the oven and gas shut off valve is turned all the way on 2 Debris in burner Burner may require cleaning Contact your distributor for assistance 3 Damaged igniter or gas valve Contact your dealer for assistance If the oven is being started for the first time Has all air been bled from the gas line Is the switch on the SV 2 an...

Страница 28: ...0 9 8 7 6 5 4 3 2 1 Yellow Red Thermo Couple Radiant Left White White Burner Disable PG 28 OF 32 M0030 07 APRIL 2017 An ongoing program of product improvement may require us to change specifications without notice WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA TEL 1 360 650 1111 FAX 1 360 650 1166 E MAIL info woodstone corp com woodstone corp com Dual Burner Phoenix Installatio...

Страница 29: ... Panel Type 4 10 9 8 7 6 5 4 3 2 1 Yellow Red Thermo Couple Radiant Left White White Burner Disable PG 29 OF 32 M0030 07 APRIL 2017 An ongoing program of product improvement may require us to change specifications without notice WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA TEL 1 360 650 1111 FAX 1 360 650 1166 E MAIL info woodstone corp com woodstone corp com Dual Burner Phoe...

Страница 30: ...the oven will cause the oven including all burners and pilots to shut off and it will be necessary to restart the oven by pressing the start switch once power is restored For additional interlock options see the Wood Stone Interlock Options supplement in the Manuals section on the website woodstone corp com or contact your distributor for additional information Dual Burner Phoenix Installation and...

Страница 31: ...tements do not constitute warranties and are not part of the contract of sale This Limited Warranty constitutes the complete final and exclusive statement with regard to warranties THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OR WARRANTY AGAINST L...

Страница 32: ...2017 Tel 1 360 650 1111 Fax 1 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...