ELECTRICAL CONNECTIONS
ELECTRICAL
The incoming 120 VAC 15 A electrical connection is made beneath the oven at the terminal strip inside the transformer box (9690,
11290, 11275), or at the junction box located at the rear left or right side all other Fire Deck models� An external cover plate provides
access to this junction box� Wiring diagrams may be found inside the Control Box, and on the transformer cover plate� Export models
may have different electrical requirements, which will be clearly marked on the wiring diagrams and the Transformer Plate�
ELECTRICAL CODE LIMITATIONS
Electrical grounding:
This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes,
with the National Electrical code, ANSI NFPA 70 or the Canadian Electrical Code, CSA C22�1 as applicable�
INTERLOCKING
If it is necessary to interlock the oven with an exhaust fan, Wood Stone recommends the following: Wire the installation in such a
way that incoming 120 VAC power to the oven is supplied only when the exhaust fan is turned on� A two pole switch controlling the
power to the fan and to the oven may be used� Consult a qualified electriciian� NEVER attempt to wire into the oven Control Box or low
voltage junction box�
ADDING TO OR ALTERING ANY OF THE WIRING IN THE OVEN CONTROL BOX OR LOW VOLTAGE JUNCTION
BOX WILL VOID THE WARRANTY.