GAS CONNECTIONS
IF YOU ARE CONVERTING A WOOD STONE OVEN FROM LP TO NATURAL GAS, OR NATURAL GAS TO LP, CONTACT THE WOOD
STONE SERVICE DEPARTMENT TO OBTAIN THE NECESSARY PARTS TO CARRY OUT THIS PROCEDURE. THIS PROCEDURE
ENTAILS CHANGING THE BURNER JETS, PILOT ORIFICES AND GAS VALVE REGULATOR SPRINGS, AS WELL AS ADJUSTING THE
BURNER MANIFOLD PRESSURES AS SPECIFIED FOR THE NEW GAS TYPE.
GAS CONNECTION
The Fire Deck 8645 and 6045 come equipped with a 3/4" FNPT connection� All gas piping up to the oven must have a minimum
inside diameter of 3/4", including all fittings and shut off valves, which should be of the full flow type�
The Fire Deck 9690, 11290, 11275, 9660, 11260 models are equipped with a 1" FNPT gas connection� All gas piping up to the oven
must have a minimum inside diameter of 1", including all fittings and shut off valves, which should be of the full flow type�
Have a licensed gas installer provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak detectors
(soap solutions or equivalent) over and around the fittings and pipe connections�
DO NOT USE A FLAME TO TEST FOR LEAKS!
Wood Stone recommends that the Fire Deck be equipped with a manual, individual shutoff valve, located between the oven and
the main gas supply, and that this shutoff valve (supplied by others) be left readily accessible� Wood Stone also recommends that
inspection and maintenance of the Burners and gas piping connections of this appliance be performed at regularly scheduled
intervals and only by professional gas appliance service agencies�
GAS INLET PRESSURE
For ovens running on natural gas, an inlet pressure of 7 to 10" W�C� is recommended to ensure optimum oven performance� Incoming
gas pressure below this range will affect oven performance, the lower the pressure the greater the negative impact� If the gas supply
pressure is greater than 14" W�C� (1/2 psi), an external regulator, supplied by others, is REQUIRED to lower the gas pressure to the
acceptable range� Issues caused by low or high gas pressure are installation issues, and will not be covered under the Warranty�
For ovens running on Propane (LP or HLP), the recommended inlet pressure to ensure optimum oven performance is 10 to 12"
W�C� Incoming gas pressure below this range will affect oven performance, the lower the pressure the greater the negative impact�
If the gas supply pressure is greater than 14" W�C� (1/2 psi), an external regulator, supplied by others, is REQUIRED to lower the gas
pressure to the acceptable range� Issues caused by low or high gas pressure are installation issues, and will not be covered under the
Warranty�
For all installations, follow best practices for proper gas line pipe sizing for the line serving the oven� To insure proper operation, all gas
piping and fittings leading up to the oven should have an inside diameter equal to or greater than that of the oven gas connection� Also
make sure that a readily accessible shut off valve (supplied by others) is installed near the oven, and in accordance with all applicable
codes� Shut off valves must be of the full-flow type, and not introduce any restriction into the gas line�
The connection to the oven should be hard-piped whenever feasible� If this is not possible, use a properly sized flexible connector
approved for this application� When using a flexible connector make sure that its design does not present any reduction in pipe
diameter or other restriction� Oven issues caused by improper pipe sizing, improper shut off valves, restrictive connectors, or any other
deficiency in the gas supply design or installation will not be covered under the oven warranty�
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1 or The Natural Gas Installation Code CAN/CGA-B149.1 as applicable.
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (14" W�C�) (3�45 kPa)�
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by others)
during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi (14" W�C�) (3�45 kPa)�
Maximum inlet gas pressure must not exceed 14" W.C. (1/2 psi)