Setup & Operation
Operation
Setup & Operation
PGdoc031914
2-18
2
Setup Mode
In setup mode, the user can adjust how the grinder functions. From the mode selection
menu, press the #4 key or scroll to the Select Mode Setup menu and press the enter key.
Scroll to the desired function and press the enter key or press the corresponding number
key. The control will timeout back to the mode selection menu after one minute of inactiv-
ity. The six functions available in setup mode are:
1. Backlight:
By default, the backlight is ON. Press the down arrow key to turn the backlight
OFF. If the backlight is OFF, press the up arrow key to turn it ON.
2. Idx Fault Adj:
The control measures the amount of current drawn by the cam index
motor. If the number of over-current pulses exceeds the set value in the allotted amount
of time, and error will occur. The value for this setting can be set between 10-95. The
default value is set at the maximum 95 at the factory and should not normally need to be
adjusted.
3. Idx Timer Adj:
This value controls the allowable time for the index cam motor to make
one revolution. The control will display the current time setting and the new time setting
entered with the number keys (range between 1 - 59). This value is set at 45 at the factory
and should not normally need to be adjusted.
4. Statistics:
The menu first displays the message “Last Blade Statistics” for 1.5 seconds
unless bypassed by pushing the enter key. The control then displays the feed rate (teeth
per minute) and the total number of teeth of the last blade processed.
5. Buzz Time Adj:
This value controls the amount of time in seconds the buzzer will sound
when a grinding cycle is complete. The value entered can be between 0 and 59 seconds
and set to 3 seconds at the factory.
6. Buzzer On/Off:
By default, the buzzer is ON. Press the down arrow key to turn the
buzzer OFF. If the buzzer is OFF, press the up arrow key to turn it ON.
The control will timeout and return to the setup select menu after 30 seconds of inactivity
in any of the above menus. To exit a menu without adjusting the value, press the escape
key. To save a new value and exit, press the enter key.