Operation
Loading The Kiln
Operation
WMDKdoc020322
4-4
4
4.4
Loading The Kiln
The loading carts should be positioned on the external track with a 2 ft. (600mm) space
between each cart so that the pack stickers bear exactly over each cart bearer.
It is important that the end of the pack which will be against the back wall when loaded
should be the “fair end” or square end of the pack.
The maximum height of the kiln charge should not exceed 1,7 meters. This will allow
sufficient airflow in the roof of the kiln to provide appropriate airflow through every part of
the pack(s).
If the kiln charge comprises of several packs stacked one on the other with bearers
between it is important that the horizontal gap created by the bearers is blanked off along
its entire length. This is to ensure that the air flow through the packs is controlled properly.
When pushing the packs into the kiln it is most important that the charge bears flat
against the back wall. If the front of the charge (door end) does not completely fill the
available space it is important to blank off the space between the pack and the door using
a piece of sheet material.
Содержание MK20-2
Страница 50: ...Operation Loading The Kiln 4 4 5 WMDKdoc020322 Operation See Figure 4 2 FIG 4 2 Blanking Sheet Material ...
Страница 54: ...Operation Temperature Controller 4 4 9 WMDKdoc020322 Operation Set the value to 95 Press the S key again ...
Страница 68: ...SECTION 9 WMUK MODULAR KILN RECORD SHEET 0 1 2 0 1 2 0 1 2 ...
Страница 69: ... 0 1 2 0 1 2 0 1 2 ...
Страница 71: ...Replacement Parts Fan Module Assembly Replacement Parts CESHdoc020322 10 2 10 10 2 Fan Module Assembly ...