Troubleshooting Guide
Power Feed Circuit Troubleshooting
Troubleshooting Guide
HD-R04doc041910
6-12
6
6.6
Power Feed Circuit Troubleshooting
LT40HD Remote
Rev. J8.01 - K4.01
NOTE:
The power feed motor is controlled by the dual-axis Accuset 2 control module,
eliminating the power feed circuit board (Rev. K5.00).
troubleshooting instructions.
LED lights are provided on the control module to help troubleshoot any feed problems
you may encounter.
See Figure 6-5.
The lights can be viewed by opening the remote junction box door.
If you have trouble determining the problem indicated by the LED lights, please note
which lights are on and call customer service for assistance.
IN
- This light normally brightens and dims as the feed rate switch is turned up or down. If
the light is always on or always off, the feed rate switch is probably miswired. An erratic
light indicates a worn or defective feed rate switch.
OV
- This light indicates an overvoltage condition. This can be caused by a defective
alternator not regulating voltage properly or a bad connection. The OV light will come on
and deactivate the power feed control output until the problem is corrected.
OL
- This light indicates an extreme overload condition of the power feed motor caused
by a mechanical bind or a short in the wiring between the motor and circuit board. The OL
light will come on and deactivate the power feed control output until the problem is cor-
rected.
FIG. 6-5
3H0470B-3
OUT
IN
PWR
OV
OL
DETAIL
See
Detail