Setup & Operation
Replacing The Blade
Setup & Operation
doc071918
2-2
2
the motor body (fan guard). If the rotation direction is incorrect, invert
the phases in the phase inverter in the power socket (electric box).
Setting the phases in the phase inverter correctly will ensure correct
rotation directions of all sawmill motors.
WARNING!
In case of a blade or drive belt brake, wait until all rotating
parts are completely stop. Failure to do so may result in serious injury.
DANGER!
It is recommended that a 30mA Ground Fault Interrupter
(GFI) be used.
2.2
Replacing The Blade
DANGER!
Always disengage the blade and shut off the sawmill motor
before changing the blade. Disconnect the power supply using the
main switch. Failure to do so will result in serious injury.
WARNING!
Always wear gloves and eye protection when handling
bandsaw blades. Changing blades is safest when done by one person!
Keep all other persons away from area when coiling, uncoiling,
carrying or changing a blade. Failure to do so may result in serious
injury.
1.
Open both blade housing covers.
2.
Turn the blade tension handle until the wheel is pulled in and the blade is loose in the blade housing.
3.
Lift the blade out of the blade housing.
4.
Install the new blade.
When installing a blade, make sure the teeth are pointing the correct direction. The teeth should be
pointing toward the operator side of the mill when you are looking at the blade below the blade
guides.
5.
Position 1 1/4” wide blades on the wheels so the gullet is 1/8" (3.0 mm) out from the edge of the
wheel.
6.
Close the blade housing covers.
7.
Use the tension handle to tension the blade correctly.