MULTISETWORKS OPERATION (OPTIONAL EQUIPMENT)
Errors
MULTISETWORKS OPERATION (OPTIONAL EQUIPMENT)Multisetworkdoc012819
3-25
3
If the saw head movement is still incorrect, change places of the wires on the PLC controller (or PLC
module) input - black and white wires.
3.7.7 Limit Switches
See Figure 3-31.
Possible error cause:
Saw head run on the up/down limit switch
limit switch or wire between limit switch and connector is damaged
wire between connector and inputs LI4 or LI5 of the drive are damaged.
When saw head run on the limit switch, it can move in the opposite direction.
Status of the limit switch can be checked on the Diagnostic screen for CanOpen devices.
FIG. 3-31