Accuset Troubleshooting
Up/Down Control Lights
Accuset Troubleshooting
AS00doc032519
3-7
3
3.3
Up/Down Control Lights
The up/down control lights are located on the back side of the Accuset front panel, next to
the power light. To access the control lights, remove the eight screws securing the
Accuset front panel. Remove the control panel from its original location without discon-
necting the wires. Turn the key switch to the on (#1) or accessory (#3) position to check
the control lights for operation.
The properly working control lights change while pushing the up/down drum switch
located on the right side of the sawmill control box. When the up/down drum switch is in
the neutral position, only the BR and BL lights should be on.
See Figure 3-3.
Only the BR and BL lights are on when the up/down drum switch is not in
use.
If the Accuset works properly and the up/down drum switch is pushed forward to move
the saw head up, only the UP, TL, and BR lights come on.
If the Accuset works okay and the up/down drum switch is pushed down to move the saw
head down, only the DN, TR, and BL lights come on.
See below to determine the cause for your problem.
FIG. 3-3
SM0284-4
UP
DN
TL
TR
BR
BL
DETAIL
See DETAIL