Setup & Operation
Using Reference Mode (Rev. B.00+ Only)
Setup & Operation
60AS-R02doc032519
1-26
1
1.6
Using Reference Mode (Rev. B.00+ Only)
While in Manual Mode, push the Toggle button to enter Reference Mode.
Push one of the four Increment Setting buttons to select a reference. Factory defaults for
buttons 1 through 4 are 3/4”, 12”, 24” and 34 1/2”. Push the up/down drum switch in the
appropriate direction to start the saw head toward the reference position. If the saw head
is already above the position and you push the drum switch up, Accuset will return to
Manual Mode. Likewise, if the saw head is below the reference position and you push the
drum switch down, Accuset returns to Manual Mode.
When the saw head reaches the target reference position, Accuset will return to Manual
Mode.
To change the stored setting for any of the four buttons, move the saw head to the
desired position. Press the Toggle button to enter Reference Mode. Push the button you
wish to store the setting and then push “Store Here”. Push the Toggle button to return to
Manual Mode.
You can also change a setting by selecting one of the four Increment Setting buttons and
changing the setting by using the Up and Down arrow buttons. Push the “Store Here” but-
ton to store the new setting.
NOTE:
The new reference setting is only stored in temporary memory and will return to
the default value when the Accuset is powered off and back on. To permanently store the
new setting, enter Configuration Menu #1 and push the “Save Settings”, then the “Save
Now” button from the Save Settings menu. Accuset will now keep the new setting until
you readjust it or reset the Accuset to factory defaults.