Alignment
Sensor Adjustment
4
4-1
SISdoc112009
Alignment
SECTION 4 ALIGNMENT
Check and align the setter each time the linear sensor is replaced.
4.1
Sensor Adjustment
1.
Turn the ON/OFF switch to the ON position.
2.
Check the air pressure. Make sure the air pressure gauge indicates 60 P.S.I. Adjust the
pressure if necessary.
3.
Place the calibration plate in the setter clamp assembly. (Use the appropriate calibration
plate as thick as the blade you want to set.) Keep the upper edge of the plate and the
sensor pin level.
4.
Press the MENU button. Push the UP arrow once to enter the DIAGNOSTIC/SETUP
menu and press the ENTER button. Press the UP button once to select the LINEAR
SENSOR ADJUST menu. Press ENTER again to confirm.
See Figure 4-1.
The sensor is adjusted properly if the black mark is located between the
arrows on the display.
NOTE:
If the black mark is not located between the arrows, the sensor needs adjustment.
FIG. 4-1
MENU
CLEAR/
ABORT
ENTER
F1
Clamp
F2
Manual
Index
F3
Manual
Bend
F4
Single
Cycle
F5
Zero
Calibrate
SI0002-1
> OK <