Attention:
When the second LAN port is set to Visualizer Mode, never connect this LAN port for the
Visualizer to your existing network infrastructure!
If this port is set to Visualizer mode, Cynap Core acts as DHCP-server on this port and this
could cause conflicts with the existing infrastructure.
Hint:
-
Connect the Visualizer straight to the dedicated port. Do not add switchers, hubs,
routers or similar between Cynap Core and the Visualizer to prevent error sources.
-
Cynap Core can be controlled with the keys of the Visualizer. The functions of keys
from the camera head are dedicated to control Cynap Core. These keys are note
have no effect to the Visualizer anymore. The IR-remote control of the Visualizer is
not effective in this setup.
-
Visualizer can be controlled with Cynap Core.
-
Cynap Core and Wolfvision Visualizer are supporting cable runs up to 100m
according Ethernet specification.
-
The behaviour of this LAN port can be changed to connect Cynap Core to a
dedicated RMS network (Room Management System). This way the built-in DHCP-
server is de-activated and a Visualizer cannot be fully integrated.
-
Be sure USB input type is not defined as “Visualizer”