The Wolf WF-300 LED Floodlite meets all relevant provisions of
the 94/9/EC (ATEX Equipment) Directive by virtue of the issued
EC Type Examination Certificate, demonstrating compliance
with all relevant Harmonised Standards and Essential Health
and Safety Requirements.
The Wolf WF-300 LED Floodlite is a high performance
lightweight portable floodlight. Constructed in marine grade
aluminium, with a polycarbonate lens: the end user must check
that these materials are suitable for the atmosphere the Floodlite
will be used in. The Floodlite can be used in Zone 1 and Zone 2
potentially explosive gas, vapour, mist and dust atmospheres
where the surface temperature / temperature class and gas
group permit.
High Voltage (HV) 100-254V AC +/- 10%
II 2GD Ex emb IIC T4 Gb (Ta = -20
o
C to +50
o
C)
Ex t IIIC T103
o
C Db IP66 & IP67.
The incoming mains cable should not exceed a temperature rise
of 61
o
C above the ambient conditions; select suitable cable and
cable gland.
Low Voltage (LV) 18-54V AC/DC +/- 10%
II 2GD Ex emb IIC T4 Gb (Ta = -20
o
C to +55
o
C)
Ex t IIIC T87
o
C Db IP66 & IP67
The incoming mains cable should not exceed a temperature rise
of 34
o
C above the ambient conditions; select suitable cable and
cable gland.
EC Type Examination Certificate:
SIRA10ATEX5117X
Notified
Baseefa Ltd.
Body:
Rockhead Business Park, Staden Lane,
Buxton, SK17 9RZ, UK
Notified body number: 1180
Harmonised standards applied:
EN60079-0:2012, EN60079-7:2007,
IEC60079-18:2009, EN60079-31:2009.
Wolf LED Floodlites are certified compliant with the
2008/108/EC EMC Directive.
The product is CE marked showing compliance with all relevant
EC Directives
Alex Jackson – Managing Director
Wolf Safety Lamp Company Ltd
IMPORTANT
Read these instructions carefully before commencing to use the
Floodlite and retain for future use.
•
Check the rating label to ensure the Floodlite is suitable for
the supply provided, ambient temperature present and IP
rating.
•
ATEX certification includes assessment of product safety at
±10% of rated voltage, running lamps outside of this voltage
tolerance will therefore invalidate the ATEX approval and
the product warranty, may result in a dangerous condition,
and could cause the product to fail prematurely.
•
If the Floodlite is to be used in areas of high vibration,
please consult with Wolf Safety.
•
ELECTROSTATIC CHARGING HAZARD Clean lens with
damp cloth.
•
The Floodlite consists of an Ex mb LED chamber and an Ex
emb terminal chamber.
•
All Floodlites have terminal blocks suitable for up to 4mm
2
live, neutral and earth.
•
ATEX approved cable glands must be used and be suitable
for the type of cable used. Any unused cable entries should
be blanked off with a suitable ATEX approved stopper plug
to maintain a minimum IP66/67 rating as marked on the
label.
•
This product is Class1 equipment and must be earthed.
Floodlites are supplied as standard with 3 core earthed
supply cables. Where the user specifically requires a 24 volt
SELV Floodlite with 2 core cable (+ve and -ve) / a 2 pole
plug, the Floodlite must be used with a separate connection
to earth via the external earth grounding point.
•
The Floodlite lens is moulded in Polycarbonate, the end
user must ensure that this is suitable for the atmosphere
the Floodlite will be used in.
•
LV 18-54Volt and 24Volt Floodlites with long cable lengths
(>20m) must be checked to ensure the calculated voltage
drop will not prevent the apparatus from operating within
the specified voltage tolerance (+/- 10%).
•
Do not connect Floodlites marked 24 volts, product
serial number No. up to 22716 (Except Serial numbers
22591 to 22690), to a centre tapped earth transformer
(CTE), as permanent damage to the product is likely to
occur.
•
Low voltage Floodlites marked 18-54 volts, product
serial No. from 22717. (Also serial numbers 22591 to
22690), can be connected to a CTE transformer.
•
24 volt LV Floodlites are Risk Group 1
When user is
≤
0.35m from the WF-300:
HV Risk Group 2.
Caution: possible hazardous optical radiation
emitted from this product DO NOT stare at the
operating lamp. May be harmful to the eye.
Special conditions for safe use (denoted by X after the
certificate number)
•
Always use the lamp in the bridle provided.
•
Except for internal wiring, not more than one single or
multiple strand lead shall be connected into either side of
any terminal, unless multiple conductors have been joined
in a suitable manner, e.g. two conductors into a single
insulated crimped boot lace ferrule.
•
Leads connected to the terminals shall be insulated for the
appropriate voltage and this insulation shall extend to within
1 mm of the metal of the terminal throat.
Wolf Safety Lamp Company
Saxon Road Works, Sheffield S8 0YA, England
Tel: +44 114 255 1051 Fax: +44 114 255 7988