background image

INSTALLATION GUIDE

Dual Fuel Ranges

Содержание DUAL FUEL RANGES

Страница 1: ...INSTALLATION GUIDE Dual Fuel Ranges...

Страница 2: ...ctions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Dual Fuel Ranges 3 Safety Instructions 4 Dual Fuel Range Specificat...

Страница 3: ...a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Wolf dual fuel ranges are manufactured for use with natural...

Страница 4: ...wall or floor where the range is to be installed must be sealed A ventilation hood is recommended for use with the Wolf dual fuel range In Massachusetts Installations and repairs must be performed by...

Страница 5: ...SURFACE 60 1527 RANGE 477 8 1216 367 8 937 HEIGHT TO COOKING SURFACE 601 8 1527 407 8 1035 5 RISER 457 8 1165 10 RISER 557 8 1419 20 RISER 47 1194 261 8 664 25 635 241 8 613 271 2 699 91 4 235 291 2 7...

Страница 6: ...olfappliance com Failure to locate the range without the proper clear ances will result in a fire hazard VENTILATION The dual fuel range must have an adequate supply of fresh air to assure proper comb...

Страница 7: ...RANGES Power supply 240 208 V AC 60 Hz with 30 amp service Maximum connected load 5 2 kW Total amps 21 amps Supply wire minimum size L1 L2 and ground 12 AWG neutral 16 AWG 48 AND 60 DUAL FUEL RANGES P...

Страница 8: ...it a certified 3 9 m long 1 2 or 3 4 ID flexible metal appliance connector is recom mended to connect the range to the gas supply line For LP gas piping or tubing size can be 1 2 minimum LP gas suppli...

Страница 9: ...essure to the regulator should never exceed 14 34 9 mb WC 5 psi 3 5 kPa for natural and LP gas The minimum line pressure is 7 17 5 mb WC for natural gas and 11 27 4 mb WC for LP gas Gas Pressure Regul...

Страница 10: ...ertop 36 914 minimum clearance from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to combustible rear wall abov...

Страница 11: ...ertop 36 914 minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to co...

Страница 12: ...minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to combustible rea...

Страница 13: ...ertop 36 914 minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to co...

Страница 14: ...ange must be level Use the adjustable front legs and the rear casters to level the range This range can tip Injury to persons could result Install the anti tip bracket supplied with the range ANTI TIP...

Страница 15: ...moval may cause damage to the porcelain oven interior or the door s Door removal should be done by a qualified service technician or installer For removal a hinge pin supplied with the range must be i...

Страница 16: ...onnect the red appliance wire to the red L2 power supply wire in the electrical box 5 Connect the ground appliance wire to the green ground house grounding wire in the electrical box Verify that power...

Страница 17: ...to test for leaks Bubbles around connections will indicate a gas leak If a leak appears close the gas shut off valve and adjust connections Check for leaks again Clean off the detergent solution Dual...

Страница 18: ...Wolf authorized service center IMPORTANT NOTE Initial lighting of the surface burners may take slightly longer as air in the system must be purged before gas can be supplied to the burner OVEN OPERATI...

Страница 19: ...customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the dual fuel range Both numbers are listed on the product rating plate located on the bottom of...

Страница 20: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 816980 REV A 8 2010...