Specifications
72 | WOLF GmbH 3066501_201910
11
Specifications
11.1 COB-2 oil condensing boiler
Oil condensing boiler
COB-2-15
COB-2-20
COB-2-29
COB-2-40
Rated output:
at 80/60°C stage 1 / 2
kW 9.2 / 14.7
13.4 / 19.5 18.9 / 28.8 27.4 / 38.5
at 50/30°C stage 1 / 2
kW 9.6 / 15.4
14.1 / 20.4 19.9 / 30.4 28.7 / 40.4
Rated load, stage 1 / 2
kW 9.2 / 14.7
13.5 / 19.6 19.0 / 29.0 27.5 / 38.7
Oil throughput, stage 1 / 2
kg/h 0.78 / 1.24 1.14 / 1.65 1.60 / 2.44 2.32 / 3.26
External diameter, heating flow
G
1½"
1½"
1½"
1½"
External diameter, heating return
G
1½"
1½"
1½"
1½"
Drain connection
1"
1"
1"
1"
Oil connection, flow/return hoses
G
⅜"
⅜"
⅜"
⅜"
Dimensions:
Height
mm
1290
1290
1290
1490
Width
mm
566
566
566
566
Depth
mm
605
605
605
605
Weight
kg
92
92
92
122
Air/flue pipe connection
mm
80/125
80/125
80/125
110/160
Air/flue gas routing
Type B23, B33, C33(x), C43(x), C53(x), C63(x), C83(x),
C93(x)
Fuel oil to DIN 51603-1/6
Standard fuel oil EL, low sulphur fuel oil EL, biofuel
oil B10
Nozzle *
Danfoss 0.30 / 80° S 0.35 / 60° S 0.45 / 80° S 0.55/80° S
Fuel oil filter
Siku max. 40 μm
CO
2
setting (casing open)
% 12.7 ± 0.3
12.7 ± 0.3
12.7 ± 0.3
12.7 ± 0.3
O
2
setting (casing open)
% 3.8 ± 0.4
3.8 ± 0.4
3.8 ± 0.4
3.8 ± 0.4
CO
2
maximum (casing closed)
%
13.5
13.5
13.5
13.5
O
2
minimum (casing closed)
%
2.7
2.7
2.7
2.7
Pump pressure stage 1
bar
5.0
8.5
9.8
14
Pump pressure stage 2
bar
13.5
17.0
24.0
25.0
Maximum negative pressure in oil line
bar
-0.3
-0.3
-0.3
-0.3
Flow temperature, factory setting:
Heat generator
°C
80
80
80
80
DHW
°C
65
65
65
65
Max. flow temperature
°C
90
90
90
90
Heating water pressure drop at Δ T=20 K
mbar
3.6
6
17
54
Heating water pressure drop at Δ T=10 K
mbar
12
21
55
205
Minimum system pressure
bar
1
1
1
1
Operating pressure
bar
1.5 - 2.5
1.5 - 2.5
1.5 - 2.5
1.5 - 2.5
Max. permissible boiler pressure
bar
3
3
3
3
Heating surface, heating water heat
exchanger
m²
2.55
2.55
3.05
3.85
Water capacity of heating water heat
exchanger
L
7.5
7.5
9.0
11.5
Efficiency:
at rated load at 80/60°C (net cv / gross cv)
% 99.7 / 94.1 99.5 / 93.9 99.6 / 94.0 99.5 / 93.9
at 30 % partial load and TR = 30°C
(net cv / gross cv)
% 104.7 / 98.8 104.1 / 98.2 104.7 / 98.8 104.3 / 98.4
Boiler standby loss qB at 70°C (EnEV)
%
0.75
0.75
0.55
0.45
Rated heat input, stage 2:
Flue gas mass flow rate
g/s
6.45
9.06
13.33
17.51
Flue gas temperature 50/30 - 80/60°C
°C
40 - 63
49 - 69
55 - 76
56 - 83
Available fan draught
Pa
65
65
105
150
Lowest heat input (stage 1):