Appendix
3066501_201910
WOLF GmbH | 83
12.3.1
System configuration 01
Direct heating circuit on the wall mounted condensing further optional mixing circuits via
mixer modules (factory setting)
Fig. 12.4
System configuration 01 - Direct heating circuit on the wall mounted condensing further
optional mixing circuits
q
Feed/heating circuit pump
w
Direct heating circuit
– Burner starts subject to demand from the direct heating circuit or optionally connected mixing circuits.
– Feed/heating circuit pump enabled as a heating circuit pump
– Boiler temperature controller; set value is specified by heating circuit or mixing circuits
– Input E2: not assigned
12.3.2
System configuration 02
One or more mixing circuits via mixer modules (no direct heating circuit on the condensing boiler)
M
Fig. 12.5
System configuration 02 - One or more mixing circuits
q
MM-2 mixer module
w
Mixing circuit1
Burner is enabled subject to demand from the connected mixing circuits.
– Boiler temperature controller; set value is specified by mixing circuits
– Input E2: not assigned
– Feed/heating circuit pump not enabled as a heating circuit pump
12.3.3
System configuration 11
i
There are three possible hydraulic schemes for system configuration 11.