iNSTallaTiON • Commissioning
© wodtke GmbH - Tübingen.
WK01_BA_190718
|
Page 22 / 76
10.3 Appliance installation
D
00000
72
15
7
1
1 Wall mounting bracket
f
Hook the appliance onto the bottom tabs of the wall mount-
ing bracket by the slots in the back of the appliance.
f
Place the appliance in an upright position.
f
Secure the appliance by pushing it towards the wall until it
audibly snaps into place in the two upper springs on the wall
mounting bracket.
D
00000
72
15
8
1
2
1 Appliance
2 Locking screw
f
Secure the appliance against unintentional release using
the supplied locking screw on the left-hand side of the wall
mounting bracket.
10.4 Removing the appliance
f
Undo and remove the locking screw from the wall mounting
bracket.
f
To release the appliance, push down the springs at the top of
the wall mounting bracket.
f
Tilt the appliance away from the wall and lift it off the bot-
tom tabs on the wall mounting bracket.
10.5 Electrical connection
WarNiNG Electrocution
- Carry out all electrical connection and installation
work in accordance with relevant regulations.
- In the case of a permanent connection, the appli-
ance must be able to be separated from the power
supply by an isolator that disconnects all poles with
at least 3 mm contact separation.
- Do not install the appliance with a fixed power
cable.
Note
- Observe the type plate. The specified voltage must
match the mains voltage.
- Ensure the on-site supply cable has an adequate
cross-section.
The appliance is delivered fully wired. The following electrical
connections are permissible:
wodtke comfort
Connection to a freely accessible standard socket
with matching plug
X
Permanent connection to an appliance junction
box with earth conductor
X
- If connecting the appliance via a socket, ensure that this is
easily accessible once the appliance has been installed.
- If connecting the appliance permanently, trim the power
cable so that it leads directly to the appliance connection
socket. Ensure that, after trimming the power cable, the
appliance can still be removed from the wall without a
problem.
11. Commissioning
The appliance is ready for operation as soon as it has been fixed
to the installation wall and connected to the mains.
f
Remove the protective film from the programming unit.
12. Troubleshooting
f
The power cable must only be replaced (for example if dam-
aged) by a qualified contractor authorised by the manufac-
turer, using an original spare part.
13. Appliance handover
Explain the functions of the appliance to the user. Draw special
attention to the safety instructions. Hand over the operating and
installation instructions to the user.