Manual  -MD150T – 27.10.2014 – v.1.3 

   page 3 

 

1.

 

 Safety and assembly rules 

 

Safety rules 

 

Prior to first start-up of the device carefully read the manual.  

 

Prior to first start-up of the device make sure all cables are properly connected.  

 

Provide  appropriate  working  conditions,  in  compliance  with  the  device 
specifications  (e.g.:  power  supply  voltage,  temperature,  maximum  current  
consumption). 

 

Prior to any modifications of cables connections, disconnect power supply voltage.  

 

Dismantling  of  the  indicator  housing  during  guarantee  agreement  period  results  in  its 
invalidation.  

 

Assembly recommendation  

In  the  environments  of  unknown  levels  of  interruptions  it  is  recommended  to  use  the  following 
means preventing against possible interruptions of the device operation:  

 

Ground or zero the metal rails on which instruments are mounted.  

 

Do not power the device from the same lines as high power devices without appropriate 
network filters.  

 

Apply power supply, sensor and signal  cables screening while screen grounding should be 
connected only on one side as close to the device as possible.  

 

Use communication cables (USB) equipped with filters in the form of ferrite beads.  

 

Avoid routing control (signal) cables in parallel with or in close vicinity of power and supply 
cables. 

 

Avoid close vicinity of devices generating high level of electromagnetic and/or pulse 
interference (high power loads, loads with phase or group power regulation).  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 
 
 
 

Содержание MD150T

Страница 1: ...t E J K s c D borzyce 16 62 045 Pniewy tel 48 61 22 27 422 fax 48 61 22 27 439 e mail wobit wobit com pl www wobit com pl MD150T Manual Digital processing unit with display for force sensors without a...

Страница 2: ...s 13 9 2 Measuring range of sensor 13 10 Technical parameters 14 Thank you for selecting our product This instruction will help you at correct service and accurate exploitation of described device Inf...

Страница 3: ...nments of unknown levels of interruptions it is recommended to use the following means preventing against possible interruptions of the device operation Ground or zero the metal rails on which instrum...

Страница 4: ...iguration and recording measurement data in PC e g to Excel file with the use of MD150 PC software MODBUS RTU allows for reading of measurements from several indicators at the same time to PLC control...

Страница 5: ...sensor Signal 3 S Signal sensor Signal 4 E Power supply sensor Excitatnion 5 TARA Tare input 5 24V 6 DIN2 Universal input 7 485A A Signal of RS485 interface 8 485B B Signal of RS485 interface 9 10 PK1...

Страница 6: ...White White Yellow Green Tab 1 Description of cable colors for force sensors of WObit s offer CAUTION In longer period of time can happen that derivation colors can change Wrong connection do not caus...

Страница 7: ...asurements 6 OFFS Offset for measuring value 999999 7 UNIT Units N kN g kg T funt 8 RATE Measurement frequency 10 Hz 80 Hz 9 FILT Level of averaging continuous filter 0 99 10 TRA Bridge range N config...

Страница 8: ...key you confirm the introduced change and with key you abort the change or exit the menu Prolonged pressing of keys or results in automatic increase decrease of a given position value 4 Configuration...

Страница 9: ...Units of measurement are set by 7 UNIT parameter The user has following units for selection 1 N Newton s 2 kN kilonewtons 2 g grams 3 kg kilograms 4 T tones 5 Funt pound Additionally 12 DP parameter...

Страница 10: ...s set with the first digit and the last 4 digits are used for password entry 0 0000 4 digit password 0 9999 Protection level 0 Settings protection above 12 DP parameter 1 Settings protection above 3 P...

Страница 11: ...ferrite beads at the cable beginning and its end Use of optically insulated USB hubs at PC side In the conditions of severe interference e g high interference of power grid the communication may not b...

Страница 12: ...ppropriate conversion Conversion of 2 registries 4 Byte into 32 Bit number REAL Registry_2 HI Byte1 Registry_2 LO Byte0 Registry_3 HI Byte3 Registry_3 LO Byte2 Number _32_bit Byte3 24 Byte2 16 Byte1 8...

Страница 13: ...ge tension force Range of measured force 0 75kN Example of models K1401 K1501 K1505 K1506 K1600 Round To measure large and small tension force Range of measured force 0 100kN Example of models KB52 KB...

Страница 14: ...zero tolerance 2 of measuring range hysteresis 0 2 of range and creep measured in time of 30 minutes 0 1 Temperature factor of zero point and constant is 0 1 of range 10o C Bridge resistance on input...

Отзывы: