WIZ1000 User’s Manual
(Version1.0)
©2009 WIZnet Co., Ltd. All Rights Reserved.
☞
For more information, visit our website at
http://www.wiznet.co.kr
Страница 1: ...WIZ1000 User s Manual Version1 0 2009 WIZnet Co Ltd All Rights Reserved For more information visit our website at http www wiznet co kr...
Страница 2: ...page WIZnet s Online Technical Support If you want to know more about WIZnet products please visit WIZnet website www wiznet co kr and you could also put your questions on Q A Board Our engineers will...
Страница 3: ...History Date Revision Changes 2009 06 26 V1 0 First Release Copyright Notice Copyright 2009 WIZnet Inc All Rights Reserved Technical Support support wiznet co kr Sales Distribution sales wiznet co kr...
Страница 4: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera...
Страница 5: ...ATION TOOL 11 3 FIRMWARE UPLOAD 23 4 SERIAL CONFIGURATION 25 4 1 SERIAL COMMAND FORMAT 25 4 2 WIZ1000 CONFIGURATION WITH SERIAL COMMAND 28 5 TELNET COM PORT OPTIONS 30 6 DEMONSTRATION AND TEST 34 6 1...
Страница 6: ...dow 24 Figure 14 Complete Uploading 24 Figure 15 Serial Configuration Console Display 29 Figure 16 Interface of Telnet Com Port Option Client 30 Figure 17 Telnet Com Port Option Client Tool Execution...
Страница 7: ...er that transmits the data sent by serial equipment as TCP IP data type and converts back the TCP IP data received through the network into serial data to transmit back to the equipment 1 1 Key Featur...
Страница 8: ...Y Embedded Protocol TCP UDP IP ARP ICMP MAC DHCP PPPoE DNS Network Interface 10 100 Mbps Auto detection RJ 45 Connector Serial Interface RS232 DB9 Serial Signal TXD RXD RTS CTS GND Serial Parameters P...
Страница 9: ...1000 Device Server CD Optional including Configuration Tool Program Firmware and Manual LAN Cable Optional 5V Power Adaptor Optional Table 2 Products Contents If there is any missing item contact to t...
Страница 10: ...and converts back the TCP IP data received through the network into serial data to transmit back to the equipment When the data is received from serial port it is sent to W5100 by MCU If any data is t...
Страница 11: ...he firmware of selected WIZ1000 is displayed in this field Enable Serial Debug Mode If this mode is checked you can monitor the status and socket message of WIZ1000 listen OK connect fail etc through...
Страница 12: ...ubnet mask and Gateway are displayed If module could not acquire network information from DHCP server IP address Gateway Address and Subnet mask will be initialized to 0 0 0 0 PPPoE WIZ1000 supports P...
Страница 13: ...to select the communication method based on TCP TCP is the protocol to establish the connection before data communication but UDP just processes the data communication without connection establishment...
Страница 14: ...1000 which is configured as TCP Server mode 2 As the connection is established data can be transmitted in both directions from the host to the WIZ1000 and from the WIZ1000 to the host TCP client mode...
Страница 15: ...But the communication port should also be defined well If the UDP mode is selected the data from serial interface can be defined where to delivery via the Sever IP Address and Port and the WIZ1000 ca...
Страница 16: ...ialog after Search button clicked as shown in Figure 7 The password can be modified by using this configuration tool and its maximum length is 8 bytes Be sure to input the correct password of your WIZ...
Страница 17: ...yed Change the value Click Setting button The configuration change will be complete The module will be initialized to the changed values re booting is processed To check configuration result click Sea...
Страница 18: ...each parameter in the drop down list By clicking the Setting button selected value can be applied Serial Data Packing Condition You can designate how the serial data can be packed to send to the Ethe...
Страница 19: ...er but needs to be delivered in frame unit If the value is 0 option is not used Size When data is collected as much as the defined size in the serial buffer it is transmitted to Ethernet If the value...
Страница 20: ...set this function is not activated In this default setting the connection is maintained even though there is no data transmission In order to close the connection the Close command should be given Th...
Страница 21: ...n is for module configuration not through network with Configuration tool but through serial communication When you want to set via serial communication check enable Please detail about serial configu...
Страница 22: ...ut password 5 Click Setting button to apply password setting 6 When any client accesses the module client should send password to server module first and then access will be allowed Telnet Com Port Op...
Страница 23: ...is properly connected to the network Complete Searching message and MAC address will be displayed on the Search Result as shown below Figure Figure 11 Board Search Window Select a module shown in Boa...
Страница 24: ...utton Figure 12 Open dialog box for uploading Do not upload any other files except for WIZ1000 application firmware file The firmware uploading status will be pop up as shown in Figure 13 Figure 13 Fi...
Страница 25: ...scriptor STX Command code Parameter ETX Length bytes 1 2 Variable 1 Table 3 Serial Configuration Frame Format Reply Frame format Descriptor STX Reply code Parameter ETX Length bytes 1 1 Variable 1 Tab...
Страница 26: ...ff 2 RTS CTS Set the serial baud rate data parity and flow control 4bytes Baud data byte parity flow WT 0 Disable 1 Enable Set the serial command method WU 0 Not Use 1 Use DNS Use or not WE xxxxxx eg...
Страница 27: ...otocol RB XXXX eg Baudrate 1 115200 2 57600 3 38400 4 19200 5 9600 6 4800 7 2400 8 1200 data byte 7 7bit 8bit parity 0 no parity 1 Odd 2 Even Flow 0 no 1 Xon Xoff 2 RTS CTS Get the serial baud rate RT...
Страница 28: ...t firmware from download page of http www wiznet co kr Figure13 Serial Configuration Enable Setting At the default status the serial configuration is disabled So click enable check box of serial confi...
Страница 29: ...ss 5 Input RI Check IP address of the module 6 Check S192 168 11 3 response Check changed IP address 7 Input WR Re boot 8 Check S response Successfully re booted 9 Module re booting Table 8 Serial Con...
Страница 30: ...ion client program and its user interface is shown in Figure 16 Figure 16 Interface of Telnet Com Port Option If the client is connected with WIZ1000 the disabled login frame and setting frame will be...
Страница 31: ...hould be clicked to tell WIZ1000 that the configuration is over If the value of any parameter is changed WIZ1000 will reboot again to apply it Since WIZ1000 is a gateway between Com port and Ethernet...
Страница 32: ...op Bit 0 Request current stop bit size Yes 1 Set stop bit to 1 Yes 2 Set stop bit to 2 No 1 5 Set stop bit to 1 5 No Flow Control 0 Request current flow control status Yes NONE Set flow control to NON...
Страница 33: ...ly replies the WILL and request command If a Com port option value is received by WIZ1000 it will not reply this command but setting Moreover any RFC2217 compliant Telnet tool can be used to communica...
Страница 34: ...low PC WIZ1000 Hardware 1 RS232 Port 2 LAN Port 1 WIZ1000 Device Server 2 Serial Cable 3 LAN Cable 4 DC5V Power Adaptor Software 1 Configuration Tool Program 2 Hyper Terminal Table 10 Testing Environm...
Страница 35: ...e STEP4 Set the Baud rate as WIZ1000 STEP5 Execute another Hyper terminal and open the TCP IP Winsock for setting IP and Port STEP6 Type some characters at the screen of serial Hyper terminal For exam...
Страница 36: ...ure 0 80 Ethernet 10 100 Base T Ethernet Auto detection Serial interface RS 232 7 2 Specification MCU 8051 Compliant FLASH 62KByte MCU Internal SRAM 16KByte MCU Internal EEPROM 2KByte MCU Internal 7 3...
Страница 37: ...J 45 PIN Assignment 7 3 2 2 RS 232 6 9 8 7 2 1 4 3 5 Pin Number Signal Description 1 H W Trigger Hardware Trigger signal Input 2 RxD Receive Data 3 TxD Transmit Data 4 EXT_GND External Power Ground In...
Страница 38: ...o defects which occur during normal use and does not extend to damage to products or parts which results from alternation repair modification faulty installation or service by anyone other than someon...
Страница 39: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information WIZnet WIZ1000...