W7500S2E-R1 serial to Ethernet module 

W7500S2E-R1 user manual 

Introduction 

W7500S2E-R1 is an industrial grade serial to Ethernet module. It supports TCP server, TCP client and UDP three 
operating  modes.  The  maximum  serial  baud  rate  is  460,800Mbps.  W7500S2E-R1  supports  WIZS2E  ConfigTool 
(Configuration Tool for Windows®), web page configuration and AT command to configure the module. 
W7500S2E-R1 uses W7500 MCU with hardwired TCP/IP protocol. This enable a faster, stable and secure Ethernet 
connectivity. With reference schematic(s) and guideline(s) in this user manual, it could be greatly reduced the time 
and difficulty of the hardware design and development when comparing with other approaches.

 

Features 

 

10/100 Mbps Ethernet interface with auto-negotiation and RJ45 connector 

 

Support TCP server, TCP client and UDP operating modes 

 

Flexible serial interface data packaging condition settings 

 

Smart Ethernet cable detection and keep alive features 

 

As DHCP client to automatically acquire IP address 

 

As DNS client to lookup domain name   

 

Support NetBIOS allows user to identify module’s name 

 

Support user password authorization for security 

 

Support serial AT command configuration method   

 

Built-in web server for browser and remote configuring 

 

Provide user-friendly configuration tool program (WIZS2E ConfigTool) 

 

Support firmware upgrade by ConfigTool

 

Specification

 

 

Serial interface: 3.3V TTL x1: TXD, RXD, GND 

 

Default Serial communication parameters 

o

 

Baud Rate: From 300bps to 460,800bps 

o

 

Data Bit: 7, 8 

o

 

Stop Bit: 1, 2 

o

 

Parity: None, Even, Odd 

o

 

Flow Control: None, CTS/RTS

 

 

Configuration methods 

o

 

WIZS2E ConfigTool 

o

 

Web based (via web browser) 

o

 

Serial AT command 

 

Power supply: Input Power: DC 3.3V 

 

Size: 44.45 x 31.75 x 23 (mm) 

 

Operating temperature: -40 ~ +85 ℃ (Industrial Grade) 

 

Storage environment: -40 ~ +85 ℃, 5 ~ 95% RH 

Version 

Date 

Remarks 

Содержание W7500S2E-R1

Страница 1: ...d UDP operating modes Flexible serial interface data packaging condition settings Smart Ethernet cable detection and keep alive features As DHCP client to automatically acquire IP address As DNS clien...

Страница 2: ...Description of the AT NAME command is updated 9 Chapter 2 2 Pin 2 of SW3 description in changes from GND to Vcc picture has also been modified 10 Updated Figure 2 4 Evaluation Board Reference Design...

Страница 3: ...MODULE AND HOST COMPUTER NETWORK DETECTION 11 4 4 HOW TO SET THE IP ADDRESS OF THE HOST COMPUTER 12 5 WIZS2E CONFIGTOOL 13 5 1 COLLECT MODULE S SETTING INFORMATION 13 5 2 MODIFY THE DEVICE SETTINGS 1...

Страница 4: ...ES 31 6 5 1 Set into TCP server mode example 31 6 5 2 TCP client mode example 33 6 5 3 UDP mode example 34 7 WEB PAGE CONFIGURATION 35 7 1 MAIN PAGE 35 7 2 BASIC SETTINGS 37 7 3 ADVANCE SETTINGS 38 7...

Страница 5: ...aracteristics The following table 1 1 and 1 2 was the result tested in 25oC environment Table 1 1 Voltage and current characteristics 1 2 1 2 Current characteristics Table 1 2 Current characteristics...

Страница 6: ...manual 2 Figure 1 1 W7500S2E R1 dimensions top view Figure 1 2 W7500S2E R1 dimensions side view 1 2 3 Thermal Characteristics Table 1 3 Thermal characters Part Number Grade Operating temperature Stora...

Страница 7: ...following figure 2 1 is the appearance of WIZS2E module From this figure we could identify there are 2 rows of pin headers on the module as hardware connectors for users J1 is a 1x12 single row 2 54m...

Страница 8: ...D O Serial output signal 7 RXD I Serial input signal 8 RTS I O Serial RTS signal 9 DEFAULT I Active low pull down over 3s for factory reset 10 RESET I Hardware reset pin 11 GND GND 12 GND GND Table 2...

Страница 9: ...board is connected to the W7500S2E R1 module the RJ45 on the evaluation board is disabled automatically TTL interface P2 Pin Assignment Pin Signal Pin Signal 1 5V 5 3V3 2 GND 6 GND 3 TX 7 RTS 4 RX 8 C...

Страница 10: ...speed Table 2 5 W7500S2E R1 evaluation board LED description Hardware connection explanation W7500S2E R1 used two sections of pin layouts in 1 x 12 pin and 1 x 11 pin designs This is to avoid pluggin...

Страница 11: ...Ethernet as the figure 2 5 E t h e r n e t Serial User Device PC Serial Serial W7500S2E R1 User Device User Device W7500S2E R1 W7500S2E R1 Figure 2 5 W7500S2E R1 module testing evaluation block diagr...

Страница 12: ...quests in TCP server mode The default port number is 5000 and it is waiting for client connections After the connection has created it will start data communication 3 2 TCP client mode TCP IP RS232 Se...

Страница 13: ...d on connection Therefore it does not guarantee the target device could receive the data correctly or not Thus it requires an upper layer communication protocol to communicate for ensuring the data ac...

Страница 14: ...the DHCP server 4 1 Module IP address factory default settings WIZS2E Serial to Ethernet module s factory default IP address 192 168 1 88 4 2 Method to get the IP address of the module No matter forgo...

Страница 15: ...55 255 0 respectively User could follow the flow diagram 4 3 to understand the communication procedure between the module and the host computer If they are in the same network segment it could communi...

Страница 16: ...Double Click Internet protocol version 4 TCP IPv4 After all these procedures you could get into the result as the following figure shows Please choose Using the following IP addresses for inputting t...

Страница 17: ...in MAC address format as the parent node for the list of information of WIZS2E module By pressing the button it shows the detail information about this module After pressing the MAC address of that s...

Страница 18: ...impossible to determine whether the wired or wireless network interface is currently used when configuring the module the tool has added a function of switching the network interface User can set the...

Страница 19: ...he WIZS2E module the user could reset the module back to factory default setting to solve the problem There are three kinds of method to factory Software ConfigTool AT command and hardware reset 5 4 1...

Страница 20: ...AULT button for more than 3 seconds to apply factory reset procedure 5 4 3 2 Factory reset through module Figure 5 3 through the module default PIN to restore factory settings W7500S2E R1 has a restor...

Страница 21: ...appropriate format will return an error AT commands have 4 types 1 Exit from data mode and changed to command mode 2 Command without parameter Format AT command r n No extra parameters or symbol after...

Страница 22: ...6 3 AT command list The following list is the AT command case insensitive list and related return value that supports by WIZS2E module The type R stands for read only R W means it could read and write...

Страница 23: ...mode AT C1_OP R W 1 0 TCP server default 1 TCP Client 3 UDP 2 Reserved 4 Not available Start Mode AT START_MODE R W 1 0 AT command mode default 1 Data transmission mode IP address Remote host AT C1_CL...

Страница 24: ...lear out serial buffer AT C1_BUF_CLS R W 1 Only available on TCP modes 0 Keeps data in serial after connection has created default 1 Clear data in serial after connected has created Data packaging len...

Страница 25: ...cription Usage AT Nil Terminal check return value OK r n Check the terminal device is it working If it is working normally with the module it will return OK value If the terminal is not working it wil...

Страница 26: ...ry current value return value DEFAULT r n default list r nCURRENT r n current list r n 6 4 2 6 Factory reset AT DEFAULT Command format Parameters Description Usage AT DEFAULT pass r n pass device pass...

Страница 27: ...mmand list 6 4 3 1 Device ID AT SN Command format Description Usage AT SN r n Nil Query current value Return value SN Value is device ID r nOK r n Device ID of the WIZS2E module for identification It...

Страница 28: ...er AT C1_PORT Command format Parameters Usage AT C1_PORT port r n port Local port number Default 5000 Define new value AT C1_PORT r n Query current value Return value C1_PORT Value is port r nOK r n T...

Страница 29: ...e r nOK r n 6 4 3 11Start Mode AT START_MODE Command format Parameters Usage AT START_MODE mode r n mode 0 AT command mode default 1 Data transmission mode Define new value AT START_MODE r n Query cur...

Страница 30: ...debugmsg r nOK r n 6 4 3 16 MAC address AT MAC Command format Parameters Usage AT MAC r n Nil Query current value Return value MAC Value is mac r nOK r n This is the MAC address of this WIZS2E This a...

Страница 31: ...ctivates DNS function This command will only available on TCP client and UDP modes 6 4 3 21 Reconnect time AT RECONTIME Command format Parameters Usage AT RECONTIME time r n time Reconnect time defaul...

Страница 32: ...14400 7 19200 8 38400 9 56000 10 57600 11 115200 Default 12 128000 13 230400 14 256000 15 460800 Define new value AT C1_BAUD r n Query current value Return value C1_BAUD Value is baud r n 6 4 4 3 Data...

Страница 33: ...value Return value C1_BUF_CLS Value is cls r n If there is disconnection during data communication serial buffer may still contain data which haven t send out This command could handle usage of those...

Страница 34: ...value C1_TCPAT Value is time r n Under TCP server mode the module will send out a keep alive package in a standard of time to check the connection is it active If the module did not receive any respo...

Страница 35: ...s link_m r n Only operate on TCP communication it will send out device message after the connection established 6 4 4 15 bytes sent by serial AT C1_SEND_NUM Command format Parameters Usage AT C1_SEND_...

Страница 36: ...n OK r n AT IP_MODE 0 r n IP_MODE Value is 0 r n OK r n AT IP 192 168 1 88 r n IP Value is 192 168 1 88 r n OK r n AT C1_PORT 5000 r n C1_PORT Value is 5000 r n OK r n AT EXIT r n Terminal check Echo...

Страница 37: ...1 r n OK r n AT C1_PORT 5000 r n C1_PORT Value is 5000 r n OK r n AT C1_CLI_IP1 192 168 1 99 r n C1_CLI_IP1 Value is 192 168 1 99 r n OK r n AT C1_CLI_PP1 5000 r n C1_CLI_PP1 Value is 5000 r n OK r n...

Страница 38: ...lue is 1 r n OK r n AT C1_PORT 5000 r n C1_PORT Value is 5000 r n OK r n AT C1_CLI_IP1 192 168 1 99 r n C1_CLI_IP1 Value is 192 168 1 99 r n OK r n AT C1_CLI_PP1 5000 r n C1_CLI_PP1 Value is 5000 r n...

Страница 39: ...o the public network IP The following is a local area network example configuration the configuration method is described below 7 1 Main page Starting the Chrome browser input the IP address of WIZS2E...

Страница 40: ...serial interface Serial Tx Shows the bytes of data sent from the serial interface Network Information DHCP on off Shows the DHCP mode is it active default off IP Address Shows the current IP address d...

Страница 41: ...way default 192 168 1 1 DNS Server Shows the DNS address default 114 114 114 114 Socket Setting Start Mode Startup mode of the module it could be AT Command Mode or Data Mode Socket Type The module s...

Страница 42: ...d set into NONE or CTS RTS mode User configurable Save Settings The button to save all these settings it shows a prompt window with Success saved message Figure 7 5 Web page prompt Save Success Reset...

Страница 43: ...0 disable maximum size 2048 bytes Reconnection Time ms Set the time for reconnection only available in TCP client mode default 0 instant reconnection value range 0 to 60000 unit ms Inactivity Time ms...

Страница 44: ...s working more easily through serial terminal software However this may cause trouble if the serial is connected to an embedded system Turning off this function may help Default checked enable 7 4 Dev...

Страница 45: ...ssful Management Factory Default factory reset button pressing this button will activate factory reset procedure It shows a prompt window for re confirmation is procedure please click OK for factory r...

Страница 46: ...mware from WIZnet H K Limited in binary format 8 1 W7500S2E R1 firmware upgrade through ConfigTool Firstly the IP address for the module needs to be in the same network segment with the host computer...

Страница 47: ...are solely responsible for the choice selection and use of WIZnet products and WIZnet assumes no liability for application assistance or the design of Purchasers products No license express or implie...