Electrical installation
INTORQ | BA 14.0197 | 04/2016
32
5.1.2
Switching suggestions
Abb. 14
INTORQ BFK464 connection diagram
Switching on
❚
K2/K4 must be switched on before or at the same time as K1/K3!
Switching off
❚
Normal - AC switching
-
K2/K4 remain closed
-
K1/K3 open
❚
Emergency stop - DC switching
-
K1/K3 and K2/K4 are opened at the same time
5.2
Bridge/half-wave rectifier (optional)
BEG-561-
-
The bridge/half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for the use with such rectifiers. Other use is only permitted with the approval of INTORQ.
Once a set over-excitation time has elapsed, the bridge/half-wave rectifiers switch over from bridge rectifi-
cation to half-wave rectification. Depending on the design of the load, an improvement of the switching be-
haviour or a reduction in performance is possible.
observe the
polarity
Brake circuit 1
observe the
polarity
Brake circuit 2
Suppressor
circuit
Brake
Suppressor
circuit
Brake
230 V AC or 400 V AC
Содержание WSG-TB.3 series
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 33: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 95: ...Notes INTORQ BA 14 0197 04 2016 48 Notes...
Страница 144: ...Notes INTORQ BA 14 0210 12 2016 48 Notes...
Страница 145: ...Notes INTORQ BA 14 0210 12 2016 49...
Страница 146: ...Notes INTORQ BA 14 0210 12 2016 50...
Страница 147: ......