Commissioning and operation
i
j
| BA 14.0197 | 11/2010
37
Contact type
Connection
Brake released
Microswitch closed
NC contact
black / grey
yes
no
no
yes
NO contact
black / blue
yes
yes
no
no
Tab. 5
Switching status of microswitch
6.2.2
Checking the manual release function
Note!
| The manual release is designed for operation using a Bowden cable.
| The braking circuits can only be released electrically.
Danger!
The drive system must be load−free. The motor must not rotate.
BFK464−XX−S−014.iso/dms
Fig. 16
Turning direction of the lever
1. Motor and brake deenergised.
2. Suspend bowden cable (not included in the delivery package) and pull with approx.
800 N.
– The rotor must rotate freely. A small residual torque is permissible.
3. Release the lever.
– Torque must be available!
The preparations for commissioning are completed.