5.6 CONTROLLER SETTING FOR SDS DC-PWM
Param. codes
Default SEMATIC
Parameter
Range
Note
04
To be set as for door configuration
KN Input
00, 01, 02
00 --> Default
01 --> Partial reopening
02 --> Machanical safety edge
05
To be set as for door configuration
Car door locking
device
00, 01
00 --> Off
01 --> On
06
To be set as for door configuration
Glass heavy door
00, 01
00 --> Off
01 --> On
19
01
Fire Fighting Mode
00, 01
00 --> Reversing system off
01 --> Reversing system reduce sensi-
tivity
22
To be set as for door configuration
Closing rotation
00, 01
00 --> Clockwise
01 --> Anticlockwise
25
00
Parking Mode
00, 01
00 --> Clutch closed
01 --> Clutch open
26
To be set as for door configuration
Clutch Type
00, 01, 02
00 --> Alu clutch standards (STD)
01 --> Expansion clutch (EXP)
02 --> Expansion clutch (EXP-B)
99
To be set as for door configuration
I/O Interface
00, 01, 02
00 --> Default type
01 --> Loni-BV type
02 --> TX-R5
Default profiles
50%
75%
100%
125%
150%
Opening Parameters
High Speed (Pc10)
30%
40%
50%
70%
90%
Low Speed (Pc11)
50%
50%
50%
50%
50%
Comfort (Pc12)
99%
90%
80%
70%
60%
Low speed end
(Pc64)
50%
50%
50%
50%
50%
Closing Parameters
High Speed (Pc13)
30%
35%
35%
50%
60%
Low Speed (Pc14)
16%
16%
16%
16%
16%
Comfort (Pc15)
99%
99%
99%
90%
90%
Rev. force setting
Max
150 N
150 N
150 N
150 N
150 N
Set (Pc09)
130 N
130 N
130 N
130 N
130 N
Min
110 N
110 N
110 N
110 N
110 N
-
Rev. Offset setting
100%
100%
100%
100%
100%
Standard Doors
Heavy Doors
PROFILE SETTING
Clutch space 90mm (EXP
type)
Clutch space 120mm
(EXP-B type)
Clutch space 90mm (EXP
type)
Clutch space 120mm