Assembly
premo
en-16
4022-D045530
Revision: 02
5.2.1 Mounting premo SP line on a machine
premo SP line
and
premo XP line
are equipped with a square flange with round through-holes for
mounting on a machine.
Alternatively
premo XP line
can have slotted holes, see Chapter 5.2.3 "Mounting premo XP line
with slotted holes on a machine (optional)".
5.2.2 Mounting premo TP line on a machine
premo TP line
is equipped with a circular flange with round through-holes for mounting on a
machine.
Coat the fastening screws with a threadlocker
(e.g. Loctite
®
243).
Fasten the servo actuator to the machine with
the fastening screws through the through-
holes (A).
Mount the servo actuator in such a way that
the name plate (B) remains legible.
Do not use any washers (e.g. plain
washers, tooth-lock washers).
For appropriate screw sizes and tightening
torques, see Chapter 9.1 "Specifications for
mounting on a machine", Tables "Tbl-11"
and "Tbl-13".
Coat the fastening screws with a threadlocker
(e.g. Loctite
®
243).
Fasten the servo actuator to the machine with
the fastening screws through the through-
holes (A).
Mount the servo actuator in such a way that
the name plate (B) remains legible.
Do not use any washers (e.g. plain
washers, tooth-lock washers).
For appropriate screw sizes and tightening
torques, see Chapter 9.1 "Specifications for
mounting on a machine", Table "Tbl-12".