6.2
Checking run-in behavior
Make sure there is
no
explosive atmosphere during the test.
After 4 running hours in maximum operating conditions, check the gearbox for leakage
between gear and motor and on the output shaft seal.
Measure the surface temperature at two points on the gear housing (on near the drive
and one near the output, see also Chapter 3.1 "Overview of gearbox components").
Consult with our Customer Service department if the maximum permissible housing
temperature is exceeded (see chapter 10.6 "Technical specifications").
Check the proper assembly of the clamping hub before startup by a maximum load test.
Increased running noises may be caused by faulty motor mounting.
If so, mount onto motor again according to the operating manual, or consult our
Customer Service department.