background image

WT901BLE BLE5.0 | manual v0707 | http://wiki.wit-motion.com/english

- 1 -

USER MANUAL

WT901BLE BLE5.0

Bluetooth 5.0 Inclinometer Sensor

Содержание WT901BLE

Страница 1: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 1 USER MANUAL WT901BLE BLE5 0 Bluetooth 5 0 Inclinometer Sensor...

Страница 2: ...at you need in the provided documents please contact our support team Our engineering team is committed to providing the required support necessary to ensure that you are successful with the operation...

Страница 3: ...n 7 2 1 2 BLE 5 0 Adapter Connection 10 2 2 Software Introduction 11 2 2 1 Main Menu 11 2 2 2 Menu of Configuration 12 2 3 Calibration 15 2 3 1 Accelerometer Calibration 15 2 3 2 Magnetic Field Calibr...

Страница 4: ...nual v0707 http wiki wit motion com english 4 3 Use Instructions with Android phone 28 3 1 APP Installation 28 3 2 Connection 29 3 3 Calibration 31 3 3 1 Acceleration Calibration 31 3 3 2 Magnetic Fie...

Страница 5: ...thm which can calculate the three axis angle accurately It is employed where the highest measurement accuracy is required WT901BLE BLE5 0 offers several advantages over competing sensor Heated for bes...

Страница 6: ...ill lead to the burning of the circuit board For proper instrument grounding use WITMOTION with its original factory made cable or accessories Do not change the baud rate because WITMOTION BLUETOOTH s...

Страница 7: ...tions with PC 2 1 PC Connection PC software is only compatible with Windows system Link to download software 2 1 1 Serial Connection Step 1 Connect the sensor with a serial converter PIN Connection VC...

Страница 8: ...which accessory for usage Link to tutorial of 3 in 1 serial converter TTL serial cable CH340 driver Link to tutorial of 6 in 1 serial converter CP2102 driver Step 3 Confirm the com port in device man...

Страница 9: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 9...

Страница 10: ...CP2102 driver link Step 1 Insert adapter into the USB port in the beginning Step 2 Power on the sensor after blue light of adapter flashes Step 3 Wait till the adapter s blue LED light keeps on means...

Страница 11: ...ide Record Record function 3D 3D DEMO Config Configuration setting Help Language English or Chinese Bluetooth Set Binding device or unbind Firmware update Option for firmware update About Minimu Info...

Страница 12: ...ual v0707 http wiki wit motion com english 12 Close Close com port 2 2 2 Menu of Configuration Menu of Configuration Button Function Read Config Reading the current configuration Calibrate Time Calibr...

Страница 13: ...ibrate Button Function Acceleration Accelerometer calibration Magnetic Field Magnetometer calibration Reset Height Reset height data to 0 only for sensor built in barometer including WT901B WTAHRS2 WT...

Страница 14: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 14 Menu of Communication Button Function Output Rate Return rate selection...

Страница 15: ...ge 2 3 1 Accelerometer Calibration Purpose The accelerometer calibration is used to remove the zero bias of the accelerometer Before calibration there will be different degrees of bias error After cal...

Страница 16: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 16 Step 4 Check the result confirm if there is 1g on Z axis acceleration...

Страница 17: ...en it is manufactured If it is not calibrated it will bring a large measurement error which will affect the accuracy of the measurement of the z axis angle of the heading angle Preparation 1 Sensors s...

Страница 18: ...p wiki wit motion com english 18 Step 3 Click OK once the calibration done Step 4 Place the sensor horizontally stationary and make the Y axis point to the north Step 5 Check the data of Z axis angle...

Страница 19: ...s angle can be used The z axis angle is an absolute angle and it takes the northeast sky as the coordinate system can not be relative to 0 degree Z axis to 0 is to make the initial angle of the z axis...

Страница 20: ...is no memory chip in the sensor module and the data can be recorded and saved on the computer Method is as follows Click Record and Start will save the data as a TXT file The saved file is in the dire...

Страница 21: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 21 It is highly recommended that data can be pasted to a Excel file In this way all data will be shown in order...

Страница 22: ...ng recorded file each time there will a BIN file created in the folder of record file in path of installed software meanwhile Recorded data playback method Step 1 Disconnect the sensor Step 2 Click Fi...

Страница 23: ...WT901BLE BLE5 0 manual v0707 http wiki wit motion com english 23 Step 4 Click Run and the Binary file will be playback When playback the rate can be editable...

Страница 24: ...t installation direction of the module is horizontal When the module needs to be installed vertically the vertical installation can be set Step 1 Rotate the module 90 degrees around the X axis Step 2...

Страница 25: ...idth Default bandwidth is 20HZ Explanation 1 The higher rate of bandwidth setting will lead to higher fluctuation in data waveform Conversely the lower rate of bandwidth data will become more fluent F...

Страница 26: ...The waveform will show more fluctuation 2 The higher rate of bandwidth will solve the data repeating problem For example if the bandwidth setting is 20Hz retrieval rate as 50Hz there will be 5 repeati...

Страница 27: ...ulated and analyzed based on the magnetic field Z axis angle will have few drift The default algorithm of WT901BLECL is 9 axis If there is magnetic field interference around installed environment it i...

Страница 28: ...1 It is required to allow for application positioning Always allowed and power on the positioning function and Bluetooth Note Paired devices can be searched without turning on positioning but accordin...

Страница 29: ...7 http wiki wit motion com english 29 3 2 Connection Step 1 Install the APK file give permission of Location and Storage Step 2 Open APP and choose BLE 5 0 Series as sensor series Step 3 power on the...

Страница 30: ...BLE5 0 manual v0707 http wiki wit motion com english 30 Step 4 When pairing is done the blue LED light of the sensor will flash and keep about one second After a few seconds the data will show automa...

Страница 31: ...tion Link to calibration demo 3 3 1 Acceleration Calibration Step 1 Keep the module horizontally stationary Step 2 Click the Calibration menu Step 3 Click the Acceleration Calibration and wait for 3 s...

Страница 32: ...menu Step 2 Click the Magnetic calibration button Step 3 Slowly rotate the module 360 around X Y Z 3 axis accordingly Step 4 After rotation click Finish Check the result The Z axis angle will have le...

Отзывы: