Installation:
The installation must be realized in accordance with IEC/EN 60079-14 and/or in accordance
with the national requirements. This equipment must be installed and used only by qualified
personnel, having knowledge concerning electrical equipment for use in potentially
explosive areas containing gas and/or dust. Qualified personnel must have knowledge
regarding the types of explosion protection. This equipment is intended to be used in zone 1,
2, 21 and 22 for groups IIB+H2 and IIIC with temperature class T5 or T85°C, it is necessary to
verify if this equipment is in accordance with the atmosphere where it is installed.
Connections:
Electric parameters power control unit Maximum supply voltage:
POE+ IEEE 802.3at/af, and AC/DC 12-28 Volts 25W
The terminals are suitable for solid and stranded wires.- *See wiring Diagram Page
Cable Glands:
The cable entry must be made in order not to alter the specific properties of terminal housing
compartment. The connection to the external circuits must be realized by cable glands or
pipe fittings covered by a separate certificate(s). If a cable gland is not used, or an entry is
open, the entry must be closed by a stopping plug covered by a separate certificate. The
diameter of the cable gland is ¾ inch NPT.
This equipment can be used with different voltage and power, the nominal parameters are
specified in the manual.
Cable: cable must be tested and certified for temperatures of 80°C or higher.
Fiber Cable:
Use a suitably certified optical fiber cable and internal connections shall
comply with requirements of IEC/EN 60079-15
Equipment Modifications:
This equipment must be installed and used in strict accordance with the instructions given in
the user documentation. This equipment contains no user-serviceable components.
Unauthorized equipment changes or modifications will invalidate all applicable regulatory
certifications and approvals.
General Safety and Operating Information:
11
Содержание TNO-X6072EPT1-Z
Страница 1: ...TNO X6072EPT1 Z TNO X8072EPT1 Z TNO X6322EPT1 Z Explosion Proof Network Camera Installation Manual ...
Страница 5: ...Labels 5 ...
Страница 14: ...14 UNBOXING ...
Страница 22: ...HT F1XX WM Wall Mount 22 ...
Страница 24: ...HT SD CM Corner Mount HARDWARE QTY 4 7 8 20 18 8 Bolts 24 ...
Страница 25: ...SD VM Vibration Mount HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT 25 ...
Страница 26: ...SD SO Standoff Mount HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT BACK 26 ...
Страница 27: ...Accessory Mounting Diagram HT F1XX WM HT SD PMA HT F1XX WM SD VM SD SO HT SD PMA 27 ...