background image

20_

 appendix

appendix

TROUBLESHOOTING

PROBLEM

SOLUTION

When an Windows 10 user accesses 
the web viewer through Chrome 
or Firefox, the sound volume of 
microphone changes periodically.  

 

~

This is what happens when microphone driver has been set to Realtek driver. 
Install the High Definition Audio device (Windows Default Driver) or the third party driver as 
the microphone driver.  

No video is displayed when accessing 
the plug-in free webviewer on Safari 
via HTTPS.

 

~

On the authentication popup window prompted when initially accessing https, click "View 
Authentication Certificate" and select the "Always trust when connecting to the designated 
webviewer IP" check box.

 

~

If the webviewer continues failing to display a video after you select "Next" on the message 
window below, press the command key + Q to exit the Safari browser, access again and 
follow the procedures stated above.

I can’t access the camera from a web 
browser.

 

~

Check to make sure that the camera’s Network settings are appropriate.

 

~

Check to make sure that all network cables have been connected properly.

 

~

If connected using DHCP, verify that the camera is able to acquire dynamic IP addresses 
without any problem.

 

~

If the camera is connected to a Broadband Router, verify that port forwarding is properly 
configured.

Viewer got disconnected during 
monitoring.

 

~

Connected Viewers become disconnected upon any change to camera or network 
configurations.

 

~

Check all network connections.

The camera connected to the network 
is not detected in the Device Manager 
program.

 

~

Turn off the firewall settings on your PC and then search the camera again.

Images overlap.

 

~

Check whether two or more cameras are set to a single multicast address instead of different 
addresses. If a single address is used for multiple cameras, the images may overlap.

No image appears.

 

~

If the transmission method is set to multicast, check whether there is a router that supports 
multicast in the LAN where the camera is connected.

Voice is not recorded even though 
audio input settings are configured.

 

~

You must enable the <Audio In> check box in <Basic> - <Video Profile>.

PROBLEM

SOLUTION

<Motion detection> of <Analytics> is 
set to <Enable>, but no notification 
e-mail reaches me even when an 
analysis event had occurred.

 

~

Verify the settings in the following sequence:
A. Check <Data & Time> settings.
B. The <Motion detection> should be set to <Enable>.
C.  Check if the <E-mail> option of <Event setup> menu is checked to use.

No signal is found at the Alarm Output 
port even when an intelligent video 
analysis event is generated.

 

~

Check alarm output port settings.

Cannot record into the Micro SD card.

 

~

Check if the Micro SD card is defective.

Micro SD card is inserted but the 
camera does not operate properly.

 

~

Check if the Micro SD card is inserted in the proper direction. Operation of any Micro SD card 
that is formatted by other devices is not guaranteed with this camera unit.

 

~

Format the Micro SD card again in <Setup> 

;

 <Event> 

;

 <Storage> menu.

Cannot record in the NAS.

 

~

Confirm that the information registered in the NAS is correct.

It reports that NAS setting has failed.

 

~

Confirm that the IP address of the NAS is valid.

 

~

Confirm that the ID/password of the NAS is valid.

 

~

Confirm that you can access the folder designated as the default folder using the ID of the 
NAS.

 

~

Confirm that the NAS SMB/CIFS items are unchecked.

 

~

Confirm that the NAS IP address and the camera IP address are in the same format. 
ex) The NAS & camera subnet mask initial value is 255.255.255.0. 
If the IP address is 192.168.20.32 then the NAS IP address should be in the range of 
192.168.20.1~192.168.20.255.

 

~

Check whether you tried to access as another user without formatting the default folder 
saved or used.

 

~

Confirm that you used recommended NAS equipment.

At the hybrid color palette mode, a 
color palette appears out of setting 
range.

 

~

You should consider that the setting range of the hybrid color palette needs some margin 
within its accuracy range.

 

~

The hybrid palette is affected by some factors such as a low emissive object, ambient 
emissive sources and low temperature variation, etc. It may cause its operation to 
malfunction.

 

~

It is recommended that it should not be used to the screen with low temperature variation 
and the region of interest should be set with objects of temperature difference in a screen.

Some noises might be visible on the 
screen.

 

~

Considered the nature of thermal camera, the time for stabilization is necessary after 
powering it on. During this time, some noises might be visible on the screen, but they will 
normally disappear after about 30 minutes. This time could be increased depending on the 
characteristics of the detector.

Содержание TNM-3620TDY

Страница 1: ...THERMAL NETWORK CAMERA User Manual TNM 3620TDY ...

Страница 2: ...rectness of the contents in this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Hanwha Techwin reserves the right to change the contents of this document without prior notice Designandspecificationsaresubjecttochangewithoutpriornotice TheinitialadministratorIDis admin andthepasswordshouldbesetwhe...

Страница 3: ... the product the camera may be damaged and malfunction If you forcibly install the product using non compliant tools the product may be damaged 18 Do not install the product in a place where chemical substances or oil mist exists or may be generated As edible oils such as soybean oil may damage or warp the product do not install the product in the kitchen or near the kitchen table This may cause d...

Страница 4: ...e mode faces could be misdetected depending on the surrounding environment The ITE is to be connected only to PoE networks without routing to the outside plant The wired LAN hub providing power over the Ethernet PoE in accordance with IEEE 802 3 at shall be a UL Listed device with the output evaluated as a Limited Power Source as defined in UL60950 1 or PS2 as defined in UL62368 1 Unit is intended...

Страница 5: ...13 13 Connecting the Camera Directly to Local Area Network 13 Connecting the Camera Directly to a DHCP Based DSL Cable Modem 14 Using Device Manager 14 Searching Camera Automatically 14 Configuring IP Address 15 Registering Camera Manually 15 Configuring IP Automatically 16 Port Range Forward Port Mapping Setup 17 Connecting to the Camera from a Shared Local PC 17 Connecting to the Camera from a R...

Страница 6: ... Transcend Product Type High endurance The compatibility varies depending on the card manufacturers and types RECOMMENDED NAS SPECIFICATIONS Recommended capacity 200GB or higher is recommended For this camera you are recommended to use a NAS with the following manufacturer s specs Recommended products QNAP NAS Synology NAS WHAT S INCLUDED Please check if your camera and accessories are all include...

Страница 7: ... for power and network connection d Power port DC 12V Used to plug the power cable e MICRO USB port Port to connect the WiFi dongle You can check the installation video through the applications installed in the smartphone Refer to Connect to WiFi dongle on page 9 Wifi dongle and OTG adapter are sold separately f Reset Button The button restores all camera settings to the factory default Press and ...

Страница 8: ...reverse direction It might damage your Micro SD card and your product When it rains or the humidity is high insertion or ejection of a Micro SD card is not recommended When installing removing the Micro SD card make sure you put the product body on a flat ground before working on it in order to prevent accidents due to loss or drop of any parts Removing a Micro SD card Gently press down on the exp...

Страница 9: ...dongle manufacturer Manufacturer Model NETIS WF2123 n300 EDIMAX EW 7811Un IP Time N100mini TP LINK TL WN823N V1 ASUS USB N13 ASUS USB N10 NANO NETGEAR WNA3100M IODATA WN G150UMW CONNECTING WITH OTHER DEVICE Grounding cable Wi Fi dongle Monitor for installation Power PoE Router J J The Test Monitor Out port of the product is provided for easier installation and is not recommended for monitoring pur...

Страница 10: ...r port of the camera J J If the power sources for PoE and DC 12 V are simultaneously turned on the device power will be supplied by both of PoE and DC 12 V You can also use a router featuring PoE to supply power to the camera It is advisable to use only one power source from PoE and DC 12 V Be careful not to reverse the polarity when you connect the power cable When the power is initially turned o...

Страница 11: ...ort of the camera with the microphone or LINE OUT port of the amplifier where the microphone is connected 2 Connect the SPEAKER port of the camera with the speaker or LINE IN port of the amplifier where the speaker is connected 3 Check the specifications for audio input Audio Codec Audio In G 711 PCM Bit Rate 64kbps Sampling Frequency 8kHz G 726 ADPCM Bit Rate 16Kbps 24Kbps 32Kbps 40Kbps Sampling ...

Страница 12: ... using the open collector method it may cause malfunction Refer to the Alarm Out Wiring Diagram when connecting devices such as a warning lamp or a siren To connect the external sensor Connect one signal line of a 2 wire sensor to the ALARM IN port and connect the other wire to the GND port Alarm In Wiring Diagram Alarm Out Wiring Diagram Sensor GND RESISTOR ALARM IN 5mA SINK RESISTOR RESISTOR VCC...

Страница 13: ...00 To change the IP address use the Device Manager For further details on Device Manager use refer to Using Device Manager Page 14 CONNECTING THE CAMERA DIRECTLY TO A DHCP BASED DSL CABLE MODEM 1 Connect the user PC directly with the network camera 2 Run the Device Manager and change the IP address of the camera so that you can use the web browser on your desktop to connect to the camera 3 Use the...

Страница 14: ... administrator HTTP Port Used to access the camera using the Internet browser The default value is 80 RTSP Port Used to control real time streaming The default value is 554 If using a Broadband Router IP Address Enter an address falling in the IP range provided by the Broadband Router ex 192 168 1 2 254 192 168 0 2 254 192 168 XXX 2 254 Subnet Mask The Subnet Mask of the Broadband Router will be t...

Страница 15: ...ISTERING CAMERA MANUALLY If the camera cannot be found using search function the camera can be registered remotely by manually inserting IP information if the camera is connected to external network 1 Click Add Devices Manually Add Device at the main page of the device manager 2 Insert the range of IP address that you search 3 Select the Model Name of the camera that you register and insert HTTP p...

Страница 16: ...ing setting is an example of setting a CISCO IP router The settings may differ depending on the connected Broadband Router model For more information refer to the user manual of the applicable router Setting up Port Range Forward for several network cameras You can set a rule of Port Forwarding on the Broadband Router device through its configuration web page A user can change each port using the ...

Страница 17: ...NTERNET On a remote computer that is in the Broadband Router s network cluster users can access cameras within a Broadband Router s network by using the camera s DDNS URL 1 Before you can access a camera in the Broadband Router network you should have set the port range forward for the Broadband Router 2 From the remote PC launch the Internet browser and type the DDNS URL address of the camera or ...

Страница 18: ...ng system to support the UPnP protocol 2 Click the camera name for search In the Windows operating system click the camera name searched from the network menu The login window is displayed Connecting via Bonjour 1 Run the client or operating system to support the Bonjour protocol 2 Click the camera name for search In the Mac operating system click the camera name searched from the Bonjour tab of S...

Страница 19: ... by using a memo pad or memorizing it LOGIN Whenever you access the camera the login window appears Enter the User ID and password to access the camera 1 Enter admin in the User name input box The administrator ID admin is fixed and can not be changed 2 Enter the password in the Password input field 3 Click Sign in If you log in successfully you can see the Live Viewer screen J J When you access t...

Страница 20: ...s event had occurred Verify the settings in the following sequence A Check Data Time settings B The Motion detection should be set to Enable C Check if the E mail option of Event setup menu is checked to use No signal is found at the Alarm Output port even when an intelligent video analysis event is generated Check alarm output port settings Cannot record into the Micro SD card Check if the Micro ...

Страница 21: ...erms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal Hanwha Techwin cares for the environment at all product manufacturing stages and is taking measures to provide customers with more environmentally friendly products The Eco mark represents Hanwha Techwin s devotion to creating environmentally friend...

Страница 22: ......

Отзывы: