10
· English
Cautions before installation
•
Before you start, you must turn off the circuit breaker for safety
purposes.
• It only can be installed at 16-24V AC power with the existing chime bell.
• Check your in-home chime whether it is a mechanical or electrical one.
• It is expected most of current mechanical chimes work properly except for one
with a special feature, etc.
• Check out the compatible chime list on the website which is updated on
monthly basis.
Installing power Stabilizer
Connecting the power Stabilizer to the Chime
1.
Find a breaker to cut off the electricity.
2.
Open the cover on your existing chime.
3.
Open the "Power Stabilizer Kit" and insert
the wire connector into the Power Stabilizer
Box.
Items to check before installation
Question
Answer
What types of walls
are appropriate for
the Installation?
Wood, Brick, Concrete, and Stucco walls are appropriate. The drill bit, driver,
screw and anchor needed for installation work will be provided. For brick and
concrete walls, you will have to prepare tools to drill into the wall.
How can I determine
whether the chime
is mechanical or
electronic?
Mechanical: there is a sound board (similar to the metal stick of xylophone)
Electronic: there is a speaker
Cautions when
installing SmartCam
D1 with the Wired
Home Chime
- The Power Stabilizer is an electrical accessory installed with a Home-Chime.
It helps ensure the camera with SmartCam D1 is receiving enough power in
normal conditions.
- Please see page 12 for details regarding the connection.
- When using the chime, be sure to also install the Power Stabilizer.
- If you do not install the Power Stabilizer, the product may not operate
properly.
What kinds of
Home Chimes are
compatible?
- Check the compatibility list before installation.
Most mechanical chimes share the same composition except for chimes
with special functions.
Please see page 20, "Home Chime Compatibility List" for details.
Can I use the product
without a chime bell?
This can be done by connecting directly to an AC adapter. Please check which
power specification is supported.
Only a 16-24V transformer can be supported.
- Use an AWG 19~23 Cable.
- An extension power cable up to 30m in length can be used.
When directly connecting a camera to a 16 -24V AC adapter transformer,
make sure that chime bell type is No. Chime(Default).
※
Path : [Setting][General]
Chime Bell Setting
(App)
After launching the App, select [General]-[Chime type] and set up the bell. For
an electric chime, the bell can be set to persist for 2 to 10 seconds.