English _
15
!
INST
ALLA
TION & CONNECTION
4.
Connect the network cable jack to the PoE+ port of the camera.
Outdoor installation
When you install it outside of the building, please waterproof it with waterproof butyl rubber tape (can be
purchased in stores) so that water does not leak from the gap of the cable connected to the outside.
1.
Connect the network cable.
2.
Wrap the black cable jacket (Area A) and the cable connection
area with waterproof (butyl rubber) tape so that more than half of
the butyl rubber tape is overlapped.
J
`
If the cable jacket is not waterproofed properly, then it can directly cause leakage. Make sure to protect the cable with a
dense layer of taping.
`
Waterproof butyl tape is made of butyl rubber that can be stretched to twice its normal length.
Connecting the installation monitor
Connect the test monitor out port of this product to the video input terminal of the monitor for installation.
`
The wiring varies depending on your monitor type and peripheral devices; please refer to the user manual for each device.
`
Please make sure the monitor and camera are turned off when connecting them.
J
`
This product is a network camera that transfers video over a network; the test monitor out port is used to set the imaging
range of the camera at installation.
`
Using the terminal for monitoring purposes may cause problems such as degradation in video quality.
`
It is not suitable for 24-hour monitoring using professional CRT monitors or TFT/LCD portable monitors.
`
Use the network transfer screen for 24-hour monitoring and storage.