English
- 79
●
setup
z
P(Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others.
z
SeQ. :
Enables setting up a sequence action for the camera in response to an alarm.
You can configure the settings of: HOME/PRESET/SWING/GROUP/TOUR/TRACE/A.PAN/OFF
alarm/aux output
z
Setting 1, 2 :
Enables selecting an Alarm Output method.
-
DETECT MODE : Displays the alarm input ports (1~4) and the
motion detection input. If you set MD Input, you
can select one from: OFF/MD.
-
AUX MODE : Both Alarm OUT/AUX OUT 1 and 2 are NC/NO
z
timer 1, 2 :
-
On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 minutes upon
the alarm occurrence.
-
MOMENTARY : The output operation will last until an alarm/AUX
event is released since its occurrence.
-
The Alarm/AUX output system is equipped with a relay circuit,
whose output port operates as below: (based on “NO”)
NO
NO
NC
COM
Alarm Out OFF
NC
COM
Alarm Out ON
z
out off 1, 2 :
-
Output of an alarm/AUX event can be forcibly terminated
when it occurred.
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Alarm Setting
Alarm Enable
OFF
Alarm Input
Alarm/AUX Output
MD Dwell Time
OFF
ALM Dwell Time HOLD
Alarm/AUX Output
Setting 1 DETECT MODE
Setting 2 DETECT MODE
Timer 1 OFF
Timer 2 OFF
Out Off 1
Out Off 2
Содержание HCP-6320A
Страница 1: ...HCP 6320A HCP 6320HA AHD SPEED DOME CAMERA User Manual ...
Страница 18: ...18_ connection installation connection installation ToconnecttoHanwhaTechwinPCDVR y y RS 485 Camera D D PC DVR ...
Страница 90: ...90_ product specifications product specifications Dimensions Indoor Model Unit mm Inch Ø152 5 98 Ø133 2 5 24 ...
Страница 92: ...MEMO ...