background image

connection

20_ connection

TO CONNECT THE DAY & NIGHT INPUT

Connect one strand of each signal line (2-strand) of the Illumination Sensor to the [DN] port, 
and connect the other strand to the [GND] port.

 

y

Alarm In Wiring Diagram

Sensor

GND

RESISTOR

DN (5mA SINK)

RESISTOR

RESISTOR

VCC_3.3V

DIODE

GND

MLCC

TRANSISTOR

External 

connection

Inside of the camera

TO CONNECT THE MOTION DETECTION OUTPUT

If devices (e.g., flashing light and siren) that exceed the voltage and current specifications are 
connected by using the open collector method, it may cause malfunction. 
Refer to the connection diagram below when connecting devices that exceed the voltage and 
current specifications.

 

y

MD Alarm Out Wiring Diagram

Warning lamp 

/ Siren power

Warning lamp / 

Siren

(-)

(+)

MD Alarm out (12VDC 20mA MAX)

RESISTOR

10K ohm

DIODE

RELAY

DC 5V or 3.3V

TRANSISTOR

GND

GND

TRANSISTOR

External connection

Inside of the camera

GND

RESISTOR

Содержание HCB-7000A

Страница 1: ...High Resolution Box Camera User Manual HCB 7000A HCB 7000PHA ...

Страница 2: ...ircumstances this document shall be reproduced distributed or changed partially or wholly without formal authorization Disclaimer Hanwha Techwin makes the best to verify the integrity and correctness of the contents in this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Hanwha Techwin reserves th...

Страница 3: ...o help you understand this manual thoroughly we ll introduce our model description HCB 7000A SERIES NTSC MODEL PAL MODEL HCB 7000AN HCB 7000AP HCB 7000PHA MODEL DESCRIPTION HCB 7000XHA _ _ SIGNAL SYSTEM N NTSC MODEL P PAL MODEL POWER SOURCE NTSC MODEL H AC 230V SIGNAL SYSTEM POWER SOURCE ...

Страница 4: ...zard do not expose this appliance to rain or moisture To prevent injury this apparatus must be securely attached to the floor wall in accordance with the installation instructions WARNING 1 Be sure to use only the standard adapter that is specified in the specification sheet Using any other adapter could cause fire electrical shock or damage to the product 2 Incorrectly connecting the power supply...

Страница 5: ...ock CAUTION 1 Do not drop objects on the product or apply strong shock to it Keep away from a location subject to excessive vibrationor magnetic interference 2 Do not install in a location subject to high temperature over 55 C low temperature below 10 C or high humidity Doing so may cause fire or electric shock 3 If you want to relocate the already installed product be sure to turn off the power a...

Страница 6: ... be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse ...

Страница 7: ...n or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus 13 Unplug this apparatus when a card is used Use caution when moving the cart apparatus combination to avoid injury f...

Страница 8: ...e product in a manner that has not been recommended the production functions performance may not be guaranteed Install the product by referring to Installation connection in the user manual 20 Installing or using the product in water can cause serious damage to the product Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on th...

Страница 9: ...onnecting to Monitor 18 Connecting to Power 19 Control via RS 485 Interface 20 To connect the Day Night Input 20 To connect the Motion Detection Output 21 Using Coaxial Communications CAMERA OPERATION 22 22 Menu Configuration 22 Menu Setup TROUBLESHOOTING 33 33 Troubleshooting SPECIFICATIONS 34 34 Specifications 36 Dimension ...

Страница 10: ...de that is appropriate for daytime or night time conditions The COLOR mode operates in daytime conditions to provide optimum colors and B W mode operates in night time conditions to enhance the definition of the image y y DC Drive Lens Support You can select Manual or DC Drive Lens from the menu y y Miscellaneous Functions HLC High Light Compensation REVERSE SHARPNESS and PRIVACY functions are pro...

Страница 11: ...English_11 INTRODUCTION COMPONENTS AND ACCESSORIES Check if the following items are included in the product package Camera Quick Manual Sheets lens mount ...

Страница 12: ... 1 4 20 UNC 20 THREAD L 4 5mm 0 2mm ISO standard or 0 178 ASA standard 2 Lens adaptor IInstall this if you use the lens 3 Auto Iris Lens Connector Used to connect Auto Iris Lens plug M M Auto shutter adaptor c mount adaptor and supporting board are not provided with the camera Please check the installed documentation of tripod for the installation of cameras 2 3 1 ...

Страница 13: ...English_13 INTRODUCTION Rear View POWER VIDEO HCB 7000A HCB 7000PHA POWER VIDEO ...

Страница 14: ...nalandconnectsto theVideo IN port of a AHD DVR 4 Power input terminal Connect the designated power supplies HCB 7000PHA High Voltage Type 5 RS 485 Control Port You can control SETUP MENU through this port by using external controllers like a Remote controller that RS 485 Communication is supported 6 D N Input Port You can switch to Day Night Mode by connecting an external signal to this port 7MD O...

Страница 15: ...pe Auto Iris lens is used Keep the lens surface clean if it becomes contaminated with dirt or fingerprints the picture qualitysuffers When Using Auto Iris Lens 1 Remove the protective glass cover from the front of the camera and fasten the auto iris lens by turning it clockwise 2 After combining the lens adjust the focus 3 Ifyoucannotfocus insertonetothreesheets providedasaccessories betweenthecam...

Страница 16: ...product and turn the CS Mount Lens clockwise to install it M M Use the lens connector shown in the following figure If the dimensions of the connector are not correct it may damage the camera or the lens may not be installed firmly If the lens is too heavy the camera becomes unbalanced and there may be problems Use a lens that weighs less than 450g When adjusting the Automatic Level Control ALC of...

Страница 17: ...ter clockwise to install it 2 Turn the C Mount lens clockwise to install it 3 After combining the lens adjust the focus 4 Ifyoucannotfocus insertonetothreesheets providedasaccessories betweenthecameraand thelens andthenreassembleandfocus INTRODUCTION C Mount Adapter C Mount Adapter C Mount Adapter C Mount Adapter C Mount Adapter C Mount Adapter ...

Страница 18: ...eo output formats of AHD CVBS The default is AHD Select the video output appropriate for your DVR CONNECTING TO POWER You can connect power as shown in the following figure not use POWE R VIDEO REC HDD ALARM NETWORK BACKUP POWER HCB 7000A AHD DVR Monitor y y For AC DC power Since the power specification supports both AC and DC connect AC 24V 500mA Adaptor or DC 12V 500mA Adaptor y y HighVoltageTyp...

Страница 19: ... is complete CONTROL VIA RS 485 INTERFACE The camera can be controlled by using external controllers like a Remote controller RS 485 Communication 1 To control by PC Connect the RS 485 control port of the camera and the serial cable through an RS 485 converter Example PCSerialPort SerialCable RS 485Converter CameraRS 485ControlPort 2 To control using a DVR or System Controller Connect the RS 485 c...

Страница 20: ...TO CONNECT THE MOTION DETECTION OUTPUT If devices e g flashing light and siren that exceed the voltage and current specifications are connected by using the open collector method it may cause malfunction Refer to the connection diagram below when connecting devices that exceed the voltage and current specifications y y MD Alarm Out Wiring Diagram Warning lamp Siren power Warning lamp Siren MD Alar...

Страница 21: ...mmunication over the coaxial cable USING COAXIAL COMMUNICATIONS y y Coaxial Communications System y y OSD Control method CAMERA DVR CONTROLLER SET MENU ENTER OSDKEY UP UPKEY JOYSTICKUP DOWN DOWNKEY JOYSTICKDOWN LEFT LEFTKEY JOYSTICKLEFT RIGHT RIGHTKEY JOYSTICKRIGHT Video Cable The camera s video output port is connected to the monitor with a BNC coaxial cable shown below REC HDD ALARM NETWORK BACK...

Страница 22: ...R OUTDOOR MANUAL AWC SET EXPOSURE BRIGHTNESS LENS SHUTTER AGC DNR RETURN BACKLIGHT OFF USERBLC HLC SPECIAL DISPLAY COMMADJ IMAGEADJ DAY NIGHT PRIVACY MOTION RETURN EXIT SAVE NOTSAVE RESET MENU SETUP Use the Function Setup switch within the camera camera operation POWER VIDEO FunctionSetupswitch HCB 7000A ...

Страница 23: ...on settings VIDEO FORMAT 1 When the SETUP menu screen is displayed select VIDEO FORMAT by using the Function Setup switch so that the arrow indicates VIDEO FORMAT 2 Select a desired mode using the Function Setup switch y y The video output can be selected from AHD CVBS M M By pressing the function setting button for more than 5 seconds you can change the setting from AHD to CVBS From CVBS you can ...

Страница 24: ...lance Use the White Balance function to adjust the screen color 1 When the SETUP menu screen is displayed select White Bal by using the Function Setup switch so that the arrow indicates White Bal 2 Select a desired mode using the Function Setup switch Select one of the following 5 modes as appropriate for your purpose y y ATW Selectthiswhenthecolortemperatureisbetween1 800Kand10 500K y y OUTDOOR U...

Страница 25: ...nation of the subject is dim If the camera is directed towards a fluorescent light or is installed in a place where illumination changes dramatically the White Balance operation may become unstable EXPOSURE 1 When the SETUP menu screen is displayed select EXPOSURE by using the Function Setup switch so that the arrow indicates EXPOSURE 2 Select a desired mode using the Function Setup switch y y BRI...

Страница 26: ...t use the AGC mode on the exposure menu it cannot be set above 1 60sec Depending on the setting range of the minimal maximal shutter the screen exposure can become saturated y y AGC OFF LOW MIDDLE HIGH VERY HIGH The higher the gain level the brighter the screen but the greater the noise y y DNR This is a method of reducing the noise If you increase the level the noise will be reduced but the video...

Страница 27: ...n to the MAIN SETUP menu M M If the white balance menu is set to manual then HLC performance can be limited Because there can be a difference in the effectiveness of HLC according to the amount of light area in the screen optimize the installation angle for the best HLC performance When dark the HLC is only activated when a bright light exceeding a specifi c size In NIGHT ONLY mode The HLC is not ...

Страница 28: ...f the SPECIAL menu screen is displayed use the Function Setup switch so that the arrow indicates COMM ADJ Select a desired mode using the Function Setup switch PROTOCOL Select the communication SAMSUNG T PELCO D PELCO P CAM ID Determines the camera s identification number between 0 and 255 DISP ID Determines whether camera ID is displayed or not BAUD RATE You can select 2400 4800 9600 19200 38400 ...

Страница 29: ...ode to adjust the thickness of an image s sharpness Increase or decrease the level of each mode to adjust the level of sharpness y y OFF Released state y y ON The setting range is 1 32 RETURN Return to the SPECIAL menu M M When the V REV or H REV mode is enabled the text on the screen does not flip If you increase the SHARPNESS level too high the picture may become distorted or noise may appear y ...

Страница 30: ...to short 3 5 sec a hunting can be caused In this situation it is recommended to use the default setting 30 sec EXTERN Ground to the grounding terminal to allow automatic switching between COLOR and B W Black White COLOR The picture is always displayed in color B W The picture is always displayed in black and white You can turn on or off the burst signal on B W mode M M If the lens mounted in the c...

Страница 31: ...the areas of motion detection SEL AREA Select from four areas that users want MODE Determine whether to use the selected area MASK Under Motion Detection If you don t want to see mosaic image on the screen you may turn MASK OFF If you wants to see mosaic image please turn it on TRANSPARENCY Adds or removes transparency from the masking area TOP BOTTOM LEFT RIGHT Area location can be adjusted RETUR...

Страница 32: ...le objects If an object moves too fast the same object should have overlapping areas between the consecutive frames If there are reflections blurs shadows created by a strong light such as direct sunlight lights and headlights Severe snow rain and wind Sunset or sunrise If the size is greater than the max size or smaller than the min size motion is not detected To avoid false detection caused by n...

Страница 33: ...tor or DVR to the proper condition y y If the camera is exposed to very strong light change the camera position The image on the screen is dark y y Adjust the contrast feature of the monitor or DVR y y If you have an intermediate device set the 75Ω Hi z properly The camera is not working properly and the surface of the camera is hot y y Check that you have properly connected the camera to an appro...

Страница 34: ...creen Display English Spanish French Portuguese German Italian Russian Polish Czech Romanian Serbian Swedish Danish Turkish Day Night Auto ICR External Color B W Backlight Compensation Off User BLC HLC Wide Dynamic Range D WDR Off On Digital Noise Reduction 2D DNR Motion Detection Off On 4 zones Privacy Masking Off On 2zones rectangle Gain Control Off Low Middle High Very High White Balance ATW Ou...

Страница 35: ... Electrical InputVoltage Current Dual 24VAC 10 300mA 12VDC 10 300mA AC 230V 50 60Hz 70mA Power Consumption Max 3 6W Max 4 5W Mechanical Color Material Black Aluminum Ivory Plastic Dimension WxHxD 59 6 68 4 92 7mm 2 35 2 69 3 65 59 6 68 4 116 6mm 2 35 2 69 4 59 Weight 186g 0 41 lb 398g 0 88 lb The specification for this product may change without prior notice for product improvement ...

Страница 36: ...36_ specifications DIMENSION Unit mm HCB 7000A ...

Страница 37: ...English_37 SPECIFICATIONS Unit mm HCB 7000PHA ...

Страница 38: ... www hanwha security com Hanwha Techwin America 500 Frank W Burr Blvd Suite 43 Teaneck NJ 07666 Toll Free 1 877 213 1222 Direct 1 201 325 6920 Fax 1 201 373 0124 www hanwha security com Hanwha Techwin Europe Heriot House Heriot Road Chertsey Surrey KT16 9DT United Kingdom Tel 44 1372 235663 Fax 44 1932 57 8101 www hanwha security eu ...

Отзывы: