connection
20_ connection
TO CONNECT THE DAY & NIGHT INPUT
Connect one strand of each signal line (2-strand) of the Illumination Sensor to the [DN] port,
and connect the other strand to the [GND] port.
y
Alarm In Wiring Diagram
Sensor
GND
RESISTOR
DN (5mA SINK)
RESISTOR
RESISTOR
VCC_3.3V
DIODE
GND
MLCC
TRANSISTOR
External
connection
Inside of the camera
TO CONNECT THE MOTION DETECTION OUTPUT
If devices (e.g., flashing light and siren) that exceed the voltage and current specifications are
connected by using the open collector method, it may cause malfunction.
Refer to the connection diagram below when connecting devices that exceed the voltage and
current specifications.
y
MD Alarm Out Wiring Diagram
Warning lamp
/ Siren power
Warning lamp /
Siren
(-)
(+)
MD Alarm out (12VDC 20mA MAX)
RESISTOR
10K ohm
DIODE
RELAY
DC 5V or 3.3V
TRANSISTOR
GND
GND
TRANSISTOR
External connection
Inside of the camera
GND
RESISTOR