WPC 2000 User Manual
1128500
Troubleshooting
5-21
If the DSV still will not reset, check to see if there are restrictions in the air supply line (e.g.,
restrictive fittings, quick-disconnect fittings, low flow filters or regulators, or clogged filter
elements) and correct if necessary. Also, check to make sure that the air supply line matches
the inlet port size of the DSV, and replace with a properly-sized supply line if it doesn’t.
Figure 5-4. Ross DM2 DSV Showing Reset Button