Initialization, Setup, and Checkout
3-39
Checking the Emergency-stop Circuit
To check the Emergency-stop circuit, do the following:
1.
Run the press in Continuous mode, and press the Emergency Stop button on the Operator
Station. The press should Emergency-stop immediately.
Figure 3-16. WPC 2000 Display Board LED Indicator Map
CHECKING THE EMERGENCY-STOP CIRCUIT IN SINGLE STROKE MODE
If your press does not run in Continuous mode, run this test while the press is making a stroke in
Single-stroke mode.
T
B
7
0
3
151
- Automatic single-stroke select
T
B
7
0
2
149
- One-hand control select
148
- Foot control select
147
- Spare
T
B
7
0
1
143
- Single stroke select
142
- Continuous stroke select
145
- Off stroke select
144
- Inch stroke select
T
B
7
0
4
154
- Operator station 1 select
153
- Operator station 2 select
157
- Micro-inch select
156
- Set auxiliary cams select
T
B
7
0
5
Display cable transmit
Display cable receive
T
B
7
0
6
J 707
WPC Settings key switch up (+)
Spare
Reset/Select button on
WPC Settings key switch down (-)
All LEDs are red except the Display cable
receive LED, which is yellow. Pin numbers
associated with LEDs are shown in
bold
.
LED positions on board are represented
schematically.
NOTICE
Содержание wpc 2000
Страница 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Страница 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Страница 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......
Страница 236: ......
Страница 237: ......
Страница 238: ......
Страница 239: ......
Страница 240: ......
Страница 241: ......
Страница 242: ......
Страница 243: ......
Страница 244: ......
Страница 245: ......
Страница 246: ......
Страница 247: ......
Страница 248: ......
Страница 249: ......
Страница 250: ......