Chapter 4 – SmartPAC PRO Program Mode
DIE PROTECTION (Optional)
(PROGRAM
–TOOL MANAGER – Select Tool – EDIT TOOL – DIE PROTECTION)
NOTICE
To initialize, program and use die protection, see
– Using DiProPAC Die Protection
CAM SWITCH (Optional)
(PROGRAM
–TOOL MANAGER – Select Tool – EDIT TOOL – CAM SWITCH)
NOTICE
To initialize, program and use programmable cams, see
PRESS SPEED
(PROGRAM
– TOOL MANAGER – Select Tool – EDIT TOOL – PRESS SPEED)
This item on the Tool Program Menu enables you to program maximum and minimum speed limits
for each tool you run on a variable-speed press. These limits apply to all operating modes -
Continuous, Single-stroke, and Inch.
When the speed of the press exceeds the maximum limit, SmartPAC PRO stops the press and
displays the fault message “Maximum press speed exceeded.” When press speed drops below the
minimum limit, SmartPAC PRO stops the press and displays the fault message “Minimum press
speed exceeded.” These fault message are documented in
You make speed settings on the Press Speed Parameters screen, Figure 4-17.
To set maximum and minimum speed limits for a tool, do the following:
1.
Select PRESS SPEED on the Tool Program Menu. The Press Speed Parameters screen displays
(Figure 4-17).
2.
Select the MAXIMUM PRESS SPEED value. The Numeric Entry window displays.
3.
Key in the desired value, following the directions in the window, and press ENTER. The window
closes, and your entry appears in the MAXIMUM PRESS SPEED field.
Содержание SmartPAC PRO
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 20: ......
Страница 22: ......
Страница 24: ......
Страница 42: ...1143100 SmartPAC PRO User Manual 42 Chapter 1 Introduction to SmartPAC PRO ...
Страница 142: ...1143100 SmartPAC PRO User Manual 142 Chapter 4 SmartPAC PRO Program Mode ...
Страница 200: ...1143100 SmartPAC PRO User Manual 200 Chapter 6 Using DiProPAC Die Protection Optional ...
Страница 222: ...1143100 SmartPAC PRO User Manual 222 Chapter 7 ProCamPAC Instructions ...
Страница 250: ...SmartPAC PRO User Manual 1143100 250 Appendix A SmartPAC PRO Preventive Maintenance PM Monitor Optional ...
Страница 254: ...1143100 SmartPAC PRO User Manual Appendix C SmartView Remote Viewing and E mail Setup 254 ...
Страница 280: ...SmartPAC PRO User Manual 1143100 280 Appendix C Reporting Downtime and Scrap to SFC ...
Страница 290: ...SmartPAC PRO User Manual 1143100 290 Index Y yellow fault 232 yellow sensor 169 ...
Страница 292: ......
Страница 294: ......
Страница 296: ......
Страница 298: ......
Страница 300: ......
Страница 301: ......
Страница 302: ......
Страница 303: ......
Страница 304: ......
Страница 305: ......
Страница 306: ......
Страница 307: ......
Страница 308: ......
Страница 309: ......
Страница 310: ......
Страница 311: ......
Страница 312: ......
Страница 313: ......
Страница 314: ......
Страница 315: ......
Страница 316: ......
Страница 317: ......
Страница 318: ......