Mounting the SMI 2 Panel Mount
Figure 2-2. SMI 2 Panel Mount: Mounting Dimensions
To install the SMI 2 Panel Mount in your enclosure or console, perform the following steps:
1.
Cut a 7.9 in. (200.1 mm) wide by 6.4 in (162.6 mm) high mounting hole.
2.
Insert the SMI 2 panel mount into the cutout ensuring that it is centered and square. Using the
holes in the SMI 2 panel mount as a guide, mark the locations of the mounting holes. Remove the
SMI 2 panel mount and drill the mounting holes in your enclosure.
Note: The holes in the SMI 2 panel mount are sized for #10 screws.