Shadow VI User Manual
1107200
Installation and Checkout
Chapter 2
page 51
3. Locate the 115V-230V voltage selector switch (S2) on the control board. It is located
just below TB1. If your AC power is 115V, check to see that "115V" is displayed in the
switch cavity. If your AC power is 230V, push the handle down.
115V
Handle.
Push
down
for 230V
Figure 2-17. Setting Voltage Selector Switch S2
4. Run the power wires to the control enclosure. If your stop circuits are 115V, the AC
wiring and stop circuits will enter the enclosure through the same flexible, liquid-tight
conduit (ideally, top). If the stop circuits are 24V, then 115V goes through the top
knockout and 24V goes through the bottom left (refer to the next section for specific
instructions). To maintain the control enclosure's NEMA 2/IP52 rating, you must use
conduit of the same rating and make proper connections to the control.
5. Make proper AC wiring connections as shown in wiring diagram Figure 6 at the end of
this manual.
6. Connect the electric service ground (green) wire to the set screw terminal on the inside
left side of the enclosure, as shown below.
Connect AC ground wire
(green) to set screw
terminal
Ground wire pre-wired
to stud on case
TB1
1
2
3
4
Figure 2-18. Connecting to Protective Earth Ground Set Screw Terminal
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......