background image

 

Version

 

0.3

1

 

Quick

 

start

 

        

iS

ensor

 U

S

 

Technical

 

specs

 

Normal

 

operating

 

voltage

 

2x

 

AA

 

1,5V

 

batteries

 

Frequency

 

range

 

                               90

8.42

 

MH z

 

Wireless

 

Range

 

Up

 

to

 

30

 

meters

 

in

 

line

 

of

 

sight

 

Temperature

 

sensor

 

accuracy

 

+/

‐ 

2,5

°

 

C

 

from

 ‐

55

°

 

C

 

to

 

+130

°

 

C

 

Motion

 

sensor

 

range

 

Max.

 

10

 

meters

 

under

 

a

 

110

° 

angle

 

Basic

 

Operations

 

 

The

 iSensor

 

can

 

detect

 

move

m

ent,

 

mea

s

ure

 

li

g

h

t

 

intensity

 

and

 

temp

e

ratu

r

e.

 

 

The

 iSensor 

can

 

trigger

 

a

 

security

 

system.

  

Mounting

 

1.

 

Use

 

a

 

flat

 

screwdriver

 

at

 

the

 

inlets

 

on

 

the

 

sides

 

to

 

gently

 

unlock

 

the

 

back

 

cover.

 

2.

 

Use

 

the

 

designated

 

holes

 

on

 

the

 

back

 

cover

 

to

 

screw

 

mount

 

the

 iSensor

.

 

For

 

optimal

 

use,

 

mount

 

the

 iSensor 

between

 

1,8 m

 

and

 

2,4m

 

above

 

ground

  

(A

 

rotating

 

bracket

 

is

 

available

 

to

 

adjust

 

the

 

direction

 

the

 iSensor 

is

 

pointing

 

to).

 

3.

 

Place

 

two

 

AA

 

1,5V

 

batteries

 

into

 

the

 

device.

 

4.

 

Mount

 

the

 iSensor 

onto

 

the

 

back

 

cover

 

and

 

be

 

sure

 

to

 

close

 

it

 

on

 

all

 

sides

 

and

 

that

 

the

 

tamper

 

gets

 

through

 

the

 

back

 

cover

 

of

 

the

 iSensor   

(indication

 

mode:

 

Tamper

 

pressed/released).

  

5.

 

After

 

3

 

seconds

 

startup

 

routine

 

begins

 

(indication

 

mode:

 

Ready

 

for

 

learn

 

mode).

 

6.

 

After

 

5

 

more

 

seconds

 

(8

 

seconds

 

in

 

total)

 

mounting

 

is

 

completed.

 

(indication

 

mode:

 

Mounting

 

successful)

 

7.

 

the

 

iSensor

 

has

 

to

 

start

 up for 10 seconds

.

 

8.

 

After

 

10 seconds the iSensor is ready for detection

.

  

Include

 

or

 

exclude

 

in

 

Z

­

Wave

 

network

 

1.

 

Make

 

sure

 

your

 

Z

Wave

 

controller

 

is

 

in

 

the

 

right

 

operation

 

mode

 

(include

 

or

 

exclude).

 

2.

 

When

 

the

 iSensor 

is

 

mounted,

 

remove

 

it

 

from

 

the

 

back

 

cover

 

as

 

explained

 

in

 

step

 

one

 

of

 

the

 

Mounting

 

instructions.

 

3.

 

Press

 

and

 

hold

 

the

 

tamper

 

for

 

1

 

second

 

(in

d

icat

i

on

 

mod

e

:

 

Re

a

d

y

 

for

 

learn

 

mo

d

e)

.

 

No

w

 

re

l

e

a

se

 

th

e

 

tamper

 

switch

 

to

 

start

 

the

 

inclusion

 

or

 

exclusion

 

process

 

(indication

 

mode:

 

Learn

 

in

 

progress).

 

4.

 

 

(The

 

product

 

will

 

start

 

NWI

 

automatically

 

after

 

unsuccessful

 

normal

 

inclusion)

 

Indication

 

mode

 

The

 

indicator

 

light

 

gives

 

various

 

statuses

 

of

 

the

 

device

 

as

 

follows:

 

1.

 

Ready

 

for

 

learn

 

mode:

   

              

indicator

 

light

 

blinks

 

every

 

second.

 

2.

 

Learn

 

in

 

progress

 

(add):

 

 

indicator

 

light

 

2

 

times

 

every

 

second.

 

3.

 

Learn

 

in

 

progress

 

(remove):

 

              

indicator

 

light

 

3

 

times

 

every

 

second.

 

4.

 

Learn

 

mode

 

success:

   

              

indicator

 

light

 

is

 

on

 

for

 

one

 

second.

 

5.

 

Learn

 

mode

 

failed:

 

 

 

indicator

 

light

 

blinks

 

8

 

times

 

rapidly.

 

6.

 

Tamper

 

pressed/released

 

 

indicator

 

light

 

blinks

 

3

 

times

 

rapidly.

 

7.

 

Mounting

 

successful

    

              

indicator

 

light

 

is

 

on

 

for

 

1

 

second.

 

Indicator

 

LED

 

Movement

 

Sensor

 

Light

 

and

 

temperature

 

sensor

 

Содержание iSensor

Страница 1: ...econds 8 seconds in total mounting is completed indication mode Mounting successful 7 the iSensor has to start up for 10 seconds 8 After 10 seconds the iSensor is ready for detection Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iSensor is mounted remove it from the back cover as explained in step one of the Mou...

Страница 2: ...truction We advise the iSensor to be mounted between 1 8m and 2 4m from the ground flat on the wall and not facing down With an optional bracket the direction the iSensor is points at can be changed up down and left right The iSensor detects movement up to 10 meters Without bracket attached it is recommended to place the iSensor in the middle of the wall see Good sensor positioning Bad sensor posi...

Страница 3: ...ke up according to the wakeup command class Include Initiator The include initiator is used when Primary and Inclusion Controllers include nodes into the network When both the include initiator have been activated simultaneously the new node will be included to the network if the node was not included previously Exclude Initiator The exclude initiator is used by Primary Controllers to exclude node...

Страница 4: ...tual value even if below 20 class 0x86 COMMAND_CLASS_VERSION This Command Class is used to obtain information about the iSensor The Z Wave library type the Z Wave protocol version and the application version will be reported class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC This will report information about the manufacturer This product will contain the manufacturer ID of Wintop Manufacturer ID of W...

Страница 5: ... is entered after detection Default 0x02 Size 1 byte Param1 mode 1 2 or 3 Mode 1 no detection possible Battery save mode Mode 2 normal operation mode send on after detection and off after given time no detection Mode 3 Z Wave chip is always on to request e g version or manufacturer id If mode is 0 or higher then 3 that value will be reported after a get but will be handled in SW as mode 2 Param2 3...

Страница 6: ...lass allows the iSensor to wake up occasionally to notify others devices that the iSensor is ready to receive commands After receiving the commands the iSensor will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user in...

Страница 7: ...on settings anymore Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURAT...

Страница 8: ...used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during configuration If the wrong size is used the frame is ignored totally Q I have configured a new value and when I request it the correct value is returned but the behavior is still the same A Some configuration parameters have limits of what they can do go to the d...

Страница 9: ......

Отзывы: