Quick start 

iModuleShutter US 

 

Technical specs   

Normal operating 
voltage  

AC110V 

~

 60Hz 

Figure 1-4 

Maximum load   

0.9HP 

Frequency range   

908.42MHz 

Wireless 

Range  

Up to 30m line of 
sight  

 

 

 

Basic Operations   

-The iModuleShutter can be remotely controlled. 

-The iModuleShutter can be add/remove from the network by continuously switch on and 
switch off the external switch 3 times quickly.

 

-The iModuleShutter’s indicator light will indicate the status of the iModuleShutter. 
 

Mounting 

1.  Turn OFF power by switching off the circuit breaker or removing the fuse and test that power 

is off before wiring! 

2.  Ensure iModuleShutter capacity matches the load requirements.   
3.  Wall Installation: Connect it with your existing external switch, 

default is one push button 

switch

. Please see below Wiring Diagrams & 

Configuration Parameters.

 

4.  Reapply power to the circuit at fuse box or circuit breaker to test the system carefully, if the 

indicator light on iModuleShutter blinks 30 seconds and then keep breathing, it means the 
installation is in good condition. 

5.  Turn OFF the power again. 
6.  For Wall Installation: Insert your external switch together with iModuleShutter into switch box 

being careful not to pinch or crush wires, and secure it with screws. Reapply power to the 
circuit at fuse box or circuit breaker. 

 

Maximum load: 

AC110V 

~

 60Hz , 0.9HP 

 

Wall Installation Wiring Diagram, connect with external switch: (see Figure 2-4, 3-4, 4-4) 

Please note: 

A 3A external fuse before the red wire Live of the iModuleShutter module 

must be installed

 in the installation for protect the iModuleShutter switch 

overload. (see Figure 2-4, 3-4) Red wire refers to Live, blue wire refers to Neutral, 
and black wire refers to connecting with switch. 

Содержание iModuleShutter

Страница 1: ...itch Please see below Wiring Diagrams Configuration Parameters 4 Reapply power to the circuit at fuse box or circuit breaker to test the system carefully if the indicator light on iModuleShutter blinks 30 seconds and then keep breathing it means the installation is in good condition 5 Turn OFF the power again 6 For Wall Installation Insert your external switch together with iModuleShutter into swi...

Страница 2: ...Version 0 4 17 April 2012 www switchdiy com Figure 2 4 Connect with 1 Gang Push Button Switch ...

Страница 3: ...Version 0 4 17 April 2012 www switchdiy com Figure 3 4 Connect with 2 Gang Push Button Switch ...

Страница 4: ...anual control Connect the terminal block COM KEY1 KEY2 with your existing external switch as per the wiring diagram Push rotate the external switch to control with UP DOWN and STOP function of the shutter motor Remote control The iModuleShutter can be remote controlled by several Z Wave controllers or devices Indication modes The indicator gives various statuses of the device as follows 1 Automati...

Страница 5: ...at receive commands and perform actions based on the command A routing slave can route Z Wave messages to other nodes in the network This device is always awake and does not go to sleep mode because it is an AC powered device This device can act as a wireless repeater to forward commands for another device in the Z Wave network to expand the range of the network This function works for every Z Wav...

Страница 6: ...nded to 150 meters indoors limit of 4 hops Supporting Command Classes Basic Class Slave with routing capabilities Generic Class Multilevel Switch Specific Class Motor Control Class C class 0x27 COMMAND_CLASS_All_Switch class 0x8E COMMAND_CLASS_Multi_Channel_Association class 0x70 COMMAND_CLASS_Configuration class 0x72 COMMAND_CLASS_Manufacturer_Specific class 0x75 COMMAND_CLASS_Protection class 0x...

Страница 7: ...ressed blinds will move down Release Up button to stop Type rangemapped Values 0 One push button 1 Two paddles with Power and Direction 2 Two toggle switch 3 Two buttons with neutral position Paramter No 7 Size 1 Default 1 Name LED mode Description Set LED indication mode Type rangemapped Values 0 Disabled 1 Show working state 2 Allways on 3 Show opened state 4 Indicator Command Class Paramter No ...

Страница 8: ... Basic and Multilevel Set values 1 99 255 would Open except 0 value that would Close Type range Values 0 Keep in permanent motion 1 1 seconds Paramter No 11 Size 1 Default 60 Name Full open time Description Time to go from closed to open state This value may differ from Full close time for some blinds due to gravity Used to estimate the current level Note that in Permanent motion mode the reported...

Страница 9: ...se relays if blind control is wired to the motor incorrectly Type rangemapped Values 0 No 1 Yes Paramter No 4 Size 1 Default 50 Name Typical click timeout Description Typical time used to differentiate click hold double and triple clicks Type range Values 1 100 in 10ms units Paramter No 5 Size 1 Default 0 Name Invert buttons Description Type rangemapped Values 0 No 1 Yes Paramter No 6 Size 1 Defau...

Страница 10: ...t used Please use external switch to add remove from the network Q I can t have my iModuleShutter included into my Z Wave network what am I doing wrong A 1 Is the controller ready to include any device into the Z Wave network If the controller is not in Include or exclude mode the iModuleShutter cannot be included or excluded 2 The iModuleShutter is already included into a Z Wave network Exclude t...

Отзывы: