background image

Horn or siren chirp duration for 

100ms

/10ms/15ms/20m

100ms

10ms

15ms

20m

7 times

Choice of ignition # 2 wire output circuits during cranking

ON

OFF

OFF

OFF

8 times

Engine run delay upon ignition at 2s / 10s

2s

10s

10s

10s

9 times

Output power delay upon lock/unlock at 0.8s / 3.6s

0.8s

3.6s

3.6s

3.6s

10 times

Unlock 2 step or channel # 3

Ch #3

2 step

2 step

2 step

11 times

Ignition on/off control door lock/unlock

O F F

ON

ON

ON

12 times

Auto rearm on/off

ON

OFF

OFF

OFF

13 times

Arm mode delay upon lock at 6s/30s

6s

30s

30s

30s

14 times

Dome light output delay time settings

6s

Содержание TR53A

Страница 1: ...icon 2 stages door unlock disarm Refer to 36 Program table 1 Another accessory 1xxx buyable from the same dealer is required After setting the system at 2 stage door unlock a press on button can unloc...

Страница 2: ...table at 36 Engine run shuts off when preset time expires When the Engine start is done the remote transmitter sounds melody with its LCD showing current status modes 9 Status Check Press button to m...

Страница 3: ...ON while in arm mode the engine start is immediately killed but siren blurts for 2 min regardless of ARM or MUTE ARM parking light flashes 2 min Both siren and parking light alert will stop after 2 mi...

Страница 4: ...tch Refer to Features Program Table at 37 While valet mode ON all other functions are still operative except for the engine start which will not be operable unless valet mode is switched OFF 30 Auto r...

Страница 5: ...led daily start time in standby mode Valet mode ON 35 Code learning of remote transmitters Follow the steps as below 1 Turn the ignition ON Engine must not be running Press and hold override switch fo...

Страница 6: ...F as shown in the chart below The shaded value is the factory default setting Features Program Table 1 Operation of buttons Pressing on Over ride switch Program Options K1 K2 K3 K4 1 time Engine runti...

Страница 7: ...gnition at 2s 10s 2s 10s 10s 10s 9 times Output power delay upon lock unlock at 0 8s 3 6s 0 8s 3 6s 3 6s 3 6s 10 times Unlock 2 step or channel 3 Ch 3 2 step 2 step 2 step 11 times Ignitionon off cont...

Страница 8: ...0 8s 0 8s 0 8s 15 times Car s inner temp mode indicated on remote s LCD Celsius Fahrenheit C F F F Be sure to mark the boxes V after any function is chosen for future reference...

Страница 9: ...ine running in this case 38 How to restore setting to factory default Follow the steps as below 5 Turn the ignition ON Engine must not be running 6 Press and release the override switch 10 times 7 Tur...

Страница 10: ...pass 17 Daily auto start time ON control its circuit enters sleep mode if the main system is disarmed 6 Engine run 18 Paing out 25 Timer count down mode 7 Remote control s battery condition 19 Temp co...

Страница 11: ...rcuit composed of a 433 92 MHz crystal and a npn transmitter The modulated output of the RF amplifier stage is coupled to the coil All the tuning and verification are done by manufacturer during the p...

Страница 12: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures l Reorient or relocate the receiving antenna...

Отзывы: