Winnix Technologies HYM360 Скачать руководство пользователя страница 1

   

UHF RFID Reader Module

 

 
 
 

UHF RFID Reader Module   

HYM360 

 

 

 

 

 

 

 

 

 

 

 

 

Winnix

 

Technologies

 

Co.,

 

Limited

 

Содержание HYM360

Страница 1: ...UHF RFID Reader Module UHF RFID Reader Module HYM360 Winnix Technologies Co Limited ...

Страница 2: ...ical Date No Item Technical Date Unit Remark 1 Fixed Current 380 mA 25dBm 2 Standby Current 1 mA EN Pin Low Level 3 Frequency Range 902 75 927 25 MHz 4 Default Working Frequency Hopping Frequency MHz Frequency Interval 250KHz 5 Fixed Power 25 dBm Max 27dBm 6 Stepping Interval 1 dBm 10 25dBm adjustable by soft 7 Label Protocol EPC C1G2 ISO18000 6C 8 Starting Time 50 ms 9 VSWR 1 5 10 Max Reading Ran...

Страница 3: ...e and strengthening rib of shell Performance Specifications FrequencyRange 860MHz 960MHz Maximum VSWR 1 3 1 Gain 9 dBi H side HPBW 70 E side HPBW 70 Polarization Circular Polarization Relative humidity 5 95 Input Impedance 50 Ω Antenna Connection N 50KFD Type N Female Physical specifications Size 258mm 258mm 56mm Weight 0 91kg without bracket Material Engineering Plastic ASA Aluminums Color Ivory ...

Страница 4: ... bracket is an optional accessory you can choose according to your special requirement 1 Installation Dimension Figure 2 Dimension of the antenna 2 Installation Steps 2 1 Horizontal Installation Step 1 Use M6 screw elastic washer and plain washer to fix the L board on the antenna please see Figure 3 Figure 3 The structure for the Step 1 in the first case Step 2 Please use M6 screw elastic washer a...

Страница 5: ... Step 1 Use M6 screw elastic washer and plain washer to fix the L board on the antenna as shown in Figure 5 Figure 5 The structure for the Step 1 in the second case Step 2 Please use M6 screw elastic washer and plain washer and Dog tooth to fix it on the horizontal and vertical bracket as shown in Figure 6 1 L board Bracket 2 M6 screw elastic washer and plain washer ...

Страница 6: ...UHF RFID Reader Module 6 9 Figure 6 The structure for the Step 2 in the second case 1 M6 screw elastic washer and plain washer 2 Dog tooth 3 M6 U style screw bolt ...

Страница 7: ...mpatibility Description 1 2 NC NC 3 6 GND Module Connecting Ground 7 VDD Input Module Supplying power 8 EN Input Module Enabling Highly Effective 9 GPIO Output 10 GPIO Output 11 UART_RX Input 12 UART_TX Output 13 16 GND Module connecting ground 17 RFOUT Bidirection Module Radio frequency Input and output interface 18 24 GND Module connecting ground ...

Страница 8: ...nce Warning This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation changes or modifications not expressly approved by the party responsible for compliance could void the user s authority t...

Страница 9: ...locate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RF Exposure Statement To maintain compliance with FCC s RF Exposure guidelines This equipment should be installed and operated with minimum d...